« Volver al listado

CVE-2019-5644

Estado: ModificadaCrítica (9.8)—

Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2019-5644",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 7.5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cve@rapid7.com",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 10,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 3.9
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cve@rapid7.com",
      "affectedData": [
        {
          "vendor": "Computing For Good",
          "product": "Basic Laboratory Information System",
          "versions": [
            {
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom",
              "lessThanOrEqual": "3.5"
            }
          ]
        }
      ]
    }
  ],
  "published": "2019-11-06T19:15:12.547",
  "references": [
    {
      "url": "https://blog.rapid7.com/2019/09/10/r7-2019-09-cve-2019-5617-cve-2019-5643-cve-2019-5644-c4g-blis-authentication-and-authorization-vulnerabilities-fixed/",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "cve@rapid7.com"
    },
    {
      "url": "https://blog.rapid7.com/2019/09/10/r7-2019-09-cve-2019-5617-cve-2019-5643-cve-2019-5644-c4g-blis-authentication-and-authorization-vulnerabilities-fixed/",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cve@rapid7.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-284"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, \"Improper Access Control.\" As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator."
    },
    {
      "lang": "es",
      "value": "Computing For Good's Basic Laboratory Information System (también se conoce como C4G BLIS) versión 3.5 y anteriores, sufre de una instancia de CWE-284, \"Improper Access Control.\" Como resultado, un usuario no autenticado puede alterar varias facetas de una cuenta de usuario, incluyendo la promoción de cualquier usuario a un administrador."
    }
  ],
  "lastModified": "2026-06-17T02:38:01.243",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:gatech:computing_for_good\\'s_basic_laboratory_information_system:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "16B48648-8C9B-4AD4-8531-6E014030D495",
              "versionEndIncluding": "3.5"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cve@rapid7.com"
}