CVE-2019-5183
Estado: ModificadaCrítica (9)—
An exploitable type confusion vulnerability exists in AMD ATIDXX64.DLL driver, versions 26.20.13031.10003, 26.20.13031.15006 and 26.20.13031.18002. A specially crafted pixel shader can cause a type confusion issue, leading to potential code execution. An attacker can provide a specially crafted shader file to trigger this vulnerability. This vulnerability can be triggered from VMware guest, affecting VMware host.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
- Puntuación base: 9
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.80%
- Percentil entre todas las CVEs puntuadas: 78
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-843
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-5183",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 6.8,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "MEDIUM",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 9,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 2.2
}
]
},
"affected": [
{
"source": "talos-cna@cisco.com",
"affectedData": [
{
"vendor": "n/a",
"product": "AMD",
"versions": [
{
"status": "affected",
"version": "AMD ATIDXX64.DLL (26.20.13031.10003, 26.20.13031.15006, 26.20.13031.18002) running on Radeon RX 550 / 550 Series VMware Workstation 15 (15.5.0 build-14665864) with Windows 10 x64 as guestVM"
}
]
}
]
}
],
"published": "2020-01-25T18:15:12.490",
"references": [
{
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0964",
"tags": [
"Third Party Advisory"
],
"source": "talos-cna@cisco.com"
},
{
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0964",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-843"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An exploitable type confusion vulnerability exists in AMD ATIDXX64.DLL driver, versions 26.20.13031.10003, 26.20.13031.15006 and 26.20.13031.18002. A specially crafted pixel shader can cause a type confusion issue, leading to potential code execution. An attacker can provide a specially crafted shader file to trigger this vulnerability. This vulnerability can be triggered from VMware guest, affecting VMware host."
},
{
"lang": "es",
"value": "Se presenta una vulnerabilidad de confusión de tipos explotable en el controlador AMD ATIDXX64.DLL, versiones 26.20.13031.10003, 26.20.13031.15006 y 26.20.13031.18002. Un sombreador de píxeles especialmente diseñado puede causar un problema de confusión de tipos, conllevando a una potencial ejecución de código. Un atacante puede proporcionar un archivo de sombreador especialmente diseñado para activar esta vulnerabilidad. Esta vulnerabilidad puede ser activada desde el VMware invitado, afectando al host VMware."
}
],
"lastModified": "2026-06-17T02:37:16.550",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:amd:atidxx64:26.20.13031.10003:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "EC82656D-2131-4934-9A1D-A51C78120B1E"
},
{
"criteria": "cpe:2.3:a:amd:atidxx64:26.20.13031.15006:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F5723683-8C9E-444E-A657-31BCF5F7E25C"
},
{
"criteria": "cpe:2.3:a:amd:atidxx64:26.20.13031.18002:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1F23D439-AB74-4CCD-BDC3-4980B78193E8"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:vmware:workstation:15.0:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "83DF9A19-ED8A-4914-96FA-D156CA9AFBC5"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "talos-cna@cisco.com"
}