« Volver al listado

CVE-2019-3933

Estado: ModificadaMedia (5.3)—

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code simply by requesting /images/browserslide.jpg via HTTP. A remote, unauthenticated attacker can use this vulnerability to watch a slideshow without knowing the access code.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2019-3933",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.3,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "vulnreport@tenable.com",
      "affectedData": [
        {
          "vendor": "Crestron",
          "product": "Crestron AirMedia",
          "versions": [
            {
              "status": "affected",
              "version": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
            }
          ]
        }
      ]
    }
  ],
  "published": "2019-04-30T21:29:00.947",
  "references": [
    {
      "url": "https://www.tenable.com/security/research/tra-2019-20",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "vulnreport@tenable.com"
    },
    {
      "url": "https://www.tenable.com/security/research/tra-2019-20",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "vulnreport@tenable.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-284"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-425"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code simply by requesting /images/browserslide.jpg via HTTP. A remote, unauthenticated attacker can use this vulnerability to watch a slideshow without knowing the access code."
    },
    {
      "lang": "es",
      "value": "Crestron AM-100 con firmware versión 1.6.0.2 y AM-101 con firmware versión 2.7.0.2 permite a cualquiera omitir el código de presentación simplemente solicitando el archivo /images/browserslide.jpg por medio de HTTP. Un atacante remoto no autenticado puede usar esta vulnerabilidad para ver una presentación de diapositivas sin conocer el código de acceso."
    }
  ],
  "lastModified": "2026-06-17T02:35:53.400",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:crestron:am-100_firmware:1.6.0.2:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "913135BE-8FB4-40BA-85D8-AD0F824493C3"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:crestron:am-100:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "081E2B1B-027D-4846-8C61-54CE2D668CD0"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:crestron:am-101_firmware:2.7.0.2:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6AC584E7-9159-48E8-B499-F5CA68663503"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:crestron:am-101:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "D0AB0523-6EFF-4C78-A8BA-B2764DBB04D0"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "vulnreport@tenable.com"
}