CVE-2019-20751
Estado: ModificadaMedia (6.8)—
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.60, DM200 before 1.0.0.61, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.26, R9000 before 1.0.4.26, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.66, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 6.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.60%
- Percentil entre todas las CVEs puntuadas: 47
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (16)
Netgear — D6100 FirmwareNetgear — Dm200 FirmwareNetgear — Ex2700 FirmwareNetgear — Ex6100 FirmwareNetgear — Ex6150 FirmwareNetgear — Ex6200 FirmwareNetgear — Ex8000 FirmwareNetgear — R7800 FirmwareNetgear — R8900 FirmwareNetgear — R9000 FirmwareNetgear — Wn2000rpt FirmwareNetgear — Wn3000rp FirmwareNetgear — Wn3100rp FirmwareNetgear — Wndr4300 FirmwareNetgear — Wndr4500 FirmwareNetgear — Wnr2000 Firmware
CWE
- CWE-787
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-20751",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5.2,
"accessVector": "ADJACENT_NETWORK",
"vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
"authentication": "SINGLE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 5.1,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "cve@mitre.org",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 6.8,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 0.9
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.8,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 0.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2020-04-16T21:15:13.067",
"references": [
{
"url": "https://kb.netgear.com/000060964/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Extenders-Gateways-and-Routers-PSV-2018-0171",
"tags": [
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://kb.netgear.com/000060964/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Extenders-Gateways-and-Routers-PSV-2018-0171",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.60, DM200 before 1.0.0.61, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.26, R9000 before 1.0.4.26, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.66, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR están afectados por un desbordamiento del búfer en la región stack de la memoria por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a 1.0.0.60, DM200 versiones anteriores a 1.0.0.61, EX2700 versiones anteriores a 1.0.1.48, EX6100v2 versiones anteriores a 1.0.1.76, EX6150v2 versiones anteriores a 1.0.1.76, EX6200v2 versiones anteriores a 1.0.1.72, EX8000 versiones anteriores a 1.0.1.180, R7800 versiones anteriores a 1.0.2.52, R8900 versiones anteriores a 1.0. 4.26, R9000 versiones anteriores a 1.0.4.26, WN2000RPTv3 versiones anteriores a 1.0.1.32, WN3000RPv2 versiones anteriores a 1.0.0.68, WN3000RPv3 versiones anteriores a 1.0.2.70, WN3100RPv2 versiones anteriores a 1.0.0.66, WNDR4300v2 versiones anteriores a 1.0.0.58, WNDR4500v3 versiones anteriores a 1.0.0.58, y WNR2000v5 versiones anteriores a 1.0.0.68."
}
],
"lastModified": "2026-06-17T02:31:07.313",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FA3E7329-F839-4DD3-921F-B9E8DEDC8F12",
"versionEndExcluding": "1.0.0.60"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6B27650A-B7FE-41E4-8231-9283CC7B8349",
"versionEndExcluding": "1.0.0.61"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "733650A8-D797-43B2-851E-1B364C9E7100",
"versionEndExcluding": "1.0.1.48"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "CC89483B-6D99-4A1B-A513-B50EA44DA963",
"versionEndExcluding": "1.0.1.76"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6100:v2:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "88DD070C-7CBD-48A5-8D77-7C3D1C502D65"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "542F7529-27DB-41F1-A8E4-FA7A596E5DCC",
"versionEndExcluding": "1.0.1.76"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6150:v2:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "49846803-C6FB-4DD3-ADA7-78B9923536F2"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3223C7E1-06DF-4CAA-89DD-611435165F49",
"versionEndExcluding": "1.0.1.72"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6200:v2:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "B4F62287-CB55-4FB1-AA39-62018654BA39"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex8000_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5F6F80A7-3B51-46FD-854E-D848F7906048",
"versionEndExcluding": "1.0.1.180"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex8000:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "8D9781C9-799A-4BDA-A027-987627A01633"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2C2195F1-18F6-4397-9D28-7A92003B7A76",
"versionEndExcluding": "1.0.2.52"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BEF7967B-5FA3-4D43-BEC5-2644FBB1D168",
"versionEndExcluding": "1.0.4.26"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D34DD834-FE59-4F04-9448-FDC385CF70F6",
"versionEndExcluding": "1.0.4.26"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "317AE6B1-BA33-49DF-A839-A49C5493996E",
"versionEndExcluding": "1.0.1.32"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "6FB1BE0D-E3CF-4C16-8C11-706B238E9934"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "663F925A-642C-4E4A-9D27-76B6EF6978F6",
"versionEndExcluding": "1.0.0.68"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wn3000rp:v2:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "3DAD97C7-458D-4547-82A4-EC7F4CFB2A90"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "DB6FCA6E-55DB-4D65-BD80-BF186C2F04FB",
"versionEndExcluding": "1.0.2.70"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A480981E-57ED-47E3-B9AB-190E4783DC04",
"versionEndExcluding": "1.0.0.66"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1DA490CC-DB27-4817-A589-61A0D221E9FD",
"versionEndExcluding": "1.0.0.58"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "652D8CA8-B56A-4403-B072-B4C245AB8EDA",
"versionEndExcluding": "1.0.0.58"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2D01DCF3-B6FD-4779-B048-DA4A963C9DEB",
"versionEndExcluding": "1.0.0.68"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}