CVE-2019-20462
Estado: AplazadaMedia (5.3)—
An issue was discovered on Alecto IVM-100 2019-11-12 devices. The device comes with a serial interface at the board level. By attaching to this serial interface and rebooting the device, a large amount of information is disclosed. This includes the view password and the password of the Wi-Fi access point that the device used.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N
- Puntuación base: 5.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.31%
- Percentil entre todas las CVEs puntuadas: 21
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-284
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-20462",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2019-20462",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-11-08T16:54:52.492218Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 5.3,
"attackVector": "PHYSICAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 4,
"exploitabilityScore": 0.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2024-11-07T21:15:05.470",
"references": [
{
"url": "https://seclists.org/fulldisclosure/2024/Jul/14",
"source": "cve@mitre.org"
},
{
"url": "https://www.alecto.nl",
"source": "cve@mitre.org"
},
{
"url": "http://seclists.org/fulldisclosure/2024/Jul/14",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-284"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Alecto IVM-100 2019-11-12 devices. The device comes with a serial interface at the board level. By attaching to this serial interface and rebooting the device, a large amount of information is disclosed. This includes the view password and the password of the Wi-Fi access point that the device used."
},
{
"lang": "es",
"value": "Se descubrió un problema en los dispositivos Alecto IVM-100 2019-11-12. El dispositivo cuenta con una interfaz serie a nivel de placa. Al conectarse a esta interfaz serie y reiniciar el dispositivo, se divulga una gran cantidad de información. Esto incluye la contraseña de visualización y la contraseña del punto de acceso Wi-Fi que el dispositivo utilizaba."
}
],
"lastModified": "2026-06-17T02:30:30.280",
"sourceIdentifier": "cve@mitre.org"
}