CVE-2019-20045
Estado: ModificadaAlta (7.5)—
The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. Specially crafted malicious packets could cause disconnection of active authentic connections or reboot of device. This is a different issue than CVE-2019-16879 and CVE-2019-20046.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.19%
- Percentil entre todas las CVEs puntuadas: 67
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-20
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-20045",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.8,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 6.9,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2020-02-14T17:15:12.723",
"references": [
{
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-20"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. Specially crafted malicious packets could cause disconnection of active authentic connections or reboot of device. This is a different issue than CVE-2019-16879 and CVE-2019-20046."
},
{
"lang": "es",
"value": "El sistema Synergy Systems & Solutions PLC & RTU, presenta una vulnerabilidad en HUSKY RTU 6049-E70 versiones de firmware 5.0 y anteriores. Los paquetes maliciosos especialmente diseñados pueden causar una desconexión de las conexiones auténticas activas o el reinicio del dispositivo. Este es un problema diferente de CVE-2019-16879 y CVE-2019-20046."
}
],
"lastModified": "2026-06-17T02:29:53.450",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:s3india:husky_rtu_6049-e70_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BD8ED218-F5C2-4D4F-AE59-9712F6EC95A4",
"versionEndIncluding": "5.0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:s3india:husky_rtu_6049-e70:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "69BE66C9-9C18-418A-ACF0-1537956F5B3B"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}