CVE-2019-19506
Estado: ModificadaAlta (7.5)—
Tenda PA6 Wi-Fi Powerline extender 1.0.1.21 is vulnerable to a denial of service, caused by an error in the "homeplugd" process. By sending a specially crafted UDP packet, an attacker could exploit this vulnerability to cause the device to reboot.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.12%
- Percentil entre todas las CVEs puntuadas: 65
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-835
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-19506",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.8,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 6.9,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2020-06-25T20:15:11.053",
"references": [
{
"url": "https://securityintelligence.com/posts/vulnerable-powerline-extenders-underline-lax-iot-security/",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://securityintelligence.com/posts/vulnerable-powerline-extenders-underline-lax-iot-security/",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-835"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda PA6 Wi-Fi Powerline extender 1.0.1.21 is vulnerable to a denial of service, caused by an error in the \"homeplugd\" process. By sending a specially crafted UDP packet, an attacker could exploit this vulnerability to cause the device to reboot."
},
{
"lang": "es",
"value": "El extensor Tenda PA6 Wi-Fi Powerline versión 1.0.1.21, es vulnerable a una denegación de servicio, causada por un error en el proceso \"homeplugd\". Mediante el envío de un paquete UDP especialmente diseñado, un atacante podría aprovechar esta vulnerabilidad para hacer que el dispositivo se reinicie"
}
],
"lastModified": "2026-06-17T02:26:46.700",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tendacn:pa6_firmware:1.0.1.21:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F6091063-6B03-4B7F-B425-B4C37B057A74"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tendacn:pa6:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "FC86310B-B452-4CEF-986C-2BB4CC535A0A"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}