« Volver al listado

CVE-2019-18248

Estado: ModificadaMedia (4.3)—

BIOTRONIK CardioMessenger II, The affected products transmit credentials in clear-text prior to switching to an encrypted communication channel. An attacker can disclose the product’s client credentials for connecting to the BIOTRONIK Remote Communication infrastructure.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2019-18248",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 3.3,
          "accessVector": "ADJACENT_NETWORK",
          "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "LOW",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 6.5,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 4.3,
          "attackVector": "ADJACENT_NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "BIOTRONIK CardioMessenger II-S T-Line, CardioMessenger II-S GSM",
          "versions": [
            {
              "status": "affected",
              "version": "CardioMessenger II-S T-Line T4APP 2.20, CardioMessenger II-S GSM T4APP 2.20"
            }
          ]
        }
      ]
    }
  ],
  "published": "2020-06-29T14:15:10.287",
  "references": [
    {
      "url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-05",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-05",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "ics-cert@hq.dhs.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-319"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-319"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "BIOTRONIK CardioMessenger II, The affected products transmit credentials in clear-text prior to switching to an encrypted communication channel. An attacker can disclose the product’s client credentials for connecting to the BIOTRONIK Remote Communication infrastructure."
    },
    {
      "lang": "es",
      "value": "BIOTRONIK CardioMessenger II, los productos afectados transmiten credenciales en texto sin cifrar antes de cambiar a un canal de comunicación cifrado. Un atacante puede revelar las credenciales del cliente del producto para conectarse a la infraestructura de Comunicación Remota de BIOTRONIK"
    }
  ],
  "lastModified": "2026-06-17T02:24:41.840",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:biotronik:cardiomessenger_ii-s_gsm_firmware:2.20:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "746B6724-81BF-4B3C-A8D0-1500CEF4C33D"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:biotronik:cardiomessenger_ii-s_gsm:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "FB7CF213-9936-4A82-A06A-78126882B79C"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:biotronik:cardiomessenger_ii-s_t-line_firmware:2.20:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "ED47244B-1693-43BC-B01A-79200CEF6B93"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:biotronik:cardiomessenger_ii-s_t-line:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "C75B7151-1853-4573-B20D-0AC269C30D6F"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}