« Volver al listado

CVE-2019-18202

Estado: ModificadaMedia (5.3)—

Information Disclosure is possible on WAGO Series PFC100 and PFC200 devices before FW12 due to improper access control. A remote attacker can check for the existence of paths and file names via crafted HTTP requests.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2019-18202",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Secondary",
        "source": "cve@mitre.org",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.0",
          "baseScore": 5.8,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 3.9
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.3,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2019-10-19T01:15:10.467",
  "references": [
    {
      "url": "https://cert.vde.com/de-de/advisories/vde-2019-017",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://cert.vde.com/de-de/advisories/vde-2019-017",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Information Disclosure is possible on WAGO Series PFC100 and PFC200 devices before FW12 due to improper access control. A remote attacker can check for the existence of paths and file names via crafted HTTP requests."
    },
    {
      "lang": "es",
      "value": "Una divulgación de información es posible en los dispositivos WAGO Series PFC100 y PFC200 versiones anteriores a FW12, debido a un control de acceso inapropiado. Un atacante remoto puede comprobar la existencia de rutas y nombres de archivos por medio de peticiones HTTP diseñadas."
    }
  ],
  "lastModified": "2026-06-17T02:24:28.207",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:wago:pfc_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "057B4DA2-1824-429D-AF18-4F12AA305AE7",
              "versionEndExcluding": "03.00.35\\(12\\)"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:wago:pfc100:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "8F636354-95A2-4B36-9666-1FA57F185432"
            },
            {
              "criteria": "cpe:2.3:h:wago:pfc200:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "688A3248-7EAA-499D-A47C-A4D4900CDBD1"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}