CVE-2019-15850
Estado: ModificadaAlta (8.8)—
eQ-3 HomeMatic CCU3 firmware version 3.41.11 allows Remote Code Execution in the ReGa.runScript method. An authenticated attacker can easily execute code and compromise the system.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 16%
- Percentil entre todas las CVEs puntuadas: 97
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-862
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-15850",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 9,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"authentication": "SINGLE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2019-10-17T14:15:10.823",
"references": [
{
"url": "https://noskill1337.github.io/homematic-ccu3-remote-code-execution",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.eq-3.com/products/homematic.html",
"tags": [
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://noskill1337.github.io/homematic-ccu3-remote-code-execution",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.eq-3.com/products/homematic.html",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-862"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "eQ-3 HomeMatic CCU3 firmware version 3.41.11 allows Remote Code Execution in the ReGa.runScript method. An authenticated attacker can easily execute code and compromise the system."
},
{
"lang": "es",
"value": "eQ-3 HomeMatic CCU3 firmware versión 3.41.11, permite la Ejecución de Código Remota en el método ReGa.runScript. Un atacante autenticado puede ejecutar código fácilmente y comprometer el sistema."
}
],
"lastModified": "2026-06-17T02:21:12.763",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:eq-3:homematic_ccu3_firmware:3.41.11:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F63AD6F8-1BE7-481B-BDDE-45234840B530"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:eq-3:homematic_ccu3:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "33113AD0-F378-49B2-BCFC-C57B52FD3A04"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}