CVE-2019-13934
Estado: ModificadaMedia (5.4)—
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflected XSS vulnerability. This issue affects: Siemens AG Polarion All versions < 19.2.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
- Puntuación base: 5.4
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.52%
- Percentil entre todas las CVEs puntuadas: 42
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-79
- CWE-79
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-13934",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 3.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"authentication": "SINGLE",
"integrityImpact": "PARTIAL",
"accessComplexity": "MEDIUM",
"availabilityImpact": "NONE",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "LOW",
"obtainAllPrivilege": false,
"exploitabilityScore": 6.8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 3.5,
"attackVector": "NETWORK",
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "LOW"
},
"impactScore": 1.4,
"exploitabilityScore": 2.1
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 5.4,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "LOW"
},
"impactScore": 2.7,
"exploitabilityScore": 2.3
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens AG",
"product": "Polarion",
"versions": [
{
"status": "affected",
"version": "All versions < 19.2"
}
]
}
]
}
],
"published": "2019-11-27T14:15:10.970",
"references": [
{
"url": "https://xavibel.com/2019/11/25/siemens-polarion-multiple-web-vulnerabilities/",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "https://xavibel.com/2019/11/25/siemens-polarion-multiple-web-vulnerabilities/",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflected XSS vulnerability. This issue affects: Siemens AG Polarion All versions < 19.2."
},
{
"lang": "es",
"value": "Una vulnerabilidad de Neutralización Inapropiada de Entrada Durante la Generación de Páginas Web (\"Cross-site Scripting\") en el cliente web de Siemens AG Polarion podría permitir a un atacante explotar una vulnerabilidad de tipo XSS reflejado. Este problema afecta a: Siemens AG Polarion Todas las versiones anteriores a la versión 19.2."
}
],
"lastModified": "2026-06-17T02:17:26.733",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:polarion:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BAD4D203-D43F-4C53-A415-4126E2F3DDE7",
"versionEndExcluding": "19.2"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "productcert@siemens.com"
}