« Volver al listado

CVE-2019-13549

Estado: ModificadaAlta (7.5)—

Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2019-13549",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "Rittal Chiller SK 3232-Series",
          "versions": [
            {
              "status": "affected",
              "version": "Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4"
            }
          ]
        }
      ]
    }
  ],
  "published": "2019-10-25T18:15:10.880",
  "references": [
    {
      "url": "http://seclists.org/fulldisclosure/2019/Oct/46",
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://www.us-cert.gov/ics/advisories/icsa-19-297-01",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "http://seclists.org/fulldisclosure/2019/Oct/46",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.us-cert.gov/ics/advisories/icsa-19-297-01",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "ics-cert@hq.dhs.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication."
    },
    {
      "lang": "es",
      "value": "El Interfaz web Rittal Chiller SK 3232-Series según el firmware Carel pCOWeb A1.5.3 - B1.2.4. El mecanismo de autenticación en los sistemas afectados no proporciona un nivel suficiente de protección contra cambios de configuración no autorizados. Las operaciones primarias, a saber, encender y apagar la unidad de enfriamiento y establecer el punto de ajuste de temperatura, se pueden modificar sin autenticación."
    }
  ],
  "lastModified": "2026-06-17T02:16:57.560",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:carel:pcoweb_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6B7B4C31-67E0-488A-9297-B8E8E158DC3E",
              "versionEndIncluding": "b1.2.4",
              "versionStartIncluding": "a1.5.3"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rittal:chiller_sk_3232:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "3FAC3FD5-429B-48BF-B519-47CAD3E718C0"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}