CVE-2019-12679
Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary SQL injections on an affected device. These vulnerabilities exist due to improper input validation. An attacker could exploit these vulnerabilities by sending crafted SQL queries to an affected device. A successful exploit could allow the attacker to view information that they are not authorized to view, make changes to the system that they are not authorized to make, and execute commands within the underlying operating system that may affect the availability of the device.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 2.96%
- Percentil entre todas las CVEs puntuadas: 87
- Fecha de la puntuación: 7/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-89
- CWE-89
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-12679",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2019-12679",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-11-20T16:51:35.180448Z"
}
}
],
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 9,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"authentication": "SINGLE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "psirt@cisco.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "psirt@cisco.com",
"affectedData": [
{
"vendor": "Cisco",
"product": "Cisco Firepower Management Center",
"versions": [
{
"status": "affected",
"version": "unspecified",
"lessThan": "n/a",
"versionType": "custom"
}
]
}
]
}
],
"published": "2019-10-02T19:15:12.453",
"references": [
{
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191002-fmc-sql-inj",
"tags": [
"Vendor Advisory"
],
"source": "psirt@cisco.com"
},
{
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191002-fmc-sql-inj",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "psirt@cisco.com",
"description": [
{
"lang": "en",
"value": "CWE-89"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-89"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary SQL injections on an affected device. These vulnerabilities exist due to improper input validation. An attacker could exploit these vulnerabilities by sending crafted SQL queries to an affected device. A successful exploit could allow the attacker to view information that they are not authorized to view, make changes to the system that they are not authorized to make, and execute commands within the underlying operating system that may affect the availability of the device."
},
{
"lang": "es",
"value": "Múltiples vulnerabilidades en la interfaz de administración basada en web del Software Cisco Firepower Management Center (FMC), podrían permitir a un atacante remoto autenticado ejecutar inyecciones SQL arbitrarias sobre un dispositivo afectado. Estas vulnerabilidades se presentan debido a una comprobación de entrada inapropiada. Un atacante podría explotar estas vulnerabilidades mediante el envío de consultas SQL creadas a un dispositivo afectado. Una explotación con éxito podría permitir al atacante visualizar información que no está autorizado de ver, llevar a cabo cambios en el sistema que no está autorizado a realizar y ejecutar comandos dentro del sistema operativo subyacente que pueden afectar la disponibilidad del dispositivo."
}
],
"lastModified": "2026-06-17T02:15:12.840",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:6.2.2:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3B5233F7-5743-467C-9C59-F5C51B47184A"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "psirt@cisco.com"
}