« Volver al listado

CVE-2019-11897

Estado: ModificadaAlta (8.6)—

A Server-Side Request Forgery (SSRF) vulnerability in the backup & restore functionality in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.3.0 allows a remote attacker to forge GET requests to arbitrary URLs. In addition, this could potentially allow an attacker to read sensitive zip files from the local server.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2019-11897",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Secondary",
        "source": "psirt@bosch.com",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.0",
          "baseScore": 8.6,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 4,
        "exploitabilityScore": 3.9
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.0",
          "baseScore": 8.6,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 4,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "psirt@bosch.com",
      "affectedData": [
        {
          "vendor": "Bosch",
          "product": "IoT Gateway Software",
          "versions": [
            {
              "status": "affected",
              "version": "unspecified",
              "lessThan": "9.3.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "vendor": "ProSyst",
          "product": "mBS SDK",
          "versions": [
            {
              "status": "affected",
              "version": "unspecified",
              "lessThan": "8.2.6",
              "versionType": "custom"
            }
          ]
        }
      ]
    }
  ],
  "published": "2019-08-21T18:15:13.273",
  "references": [
    {
      "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "psirt@bosch.com"
    },
    {
      "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "psirt@bosch.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-918"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-918"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A Server-Side Request Forgery (SSRF) vulnerability in the backup & restore functionality in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.3.0 allows a remote attacker to forge GET requests to arbitrary URLs. In addition, this could potentially allow an attacker to read sensitive zip files from the local server."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de falsificación de solicitudes del lado del servidor (SSRF) en la funcionalidad de copia de seguridad y restauración en versiones anteriores que ProSyst mBS SDK versión 8.2.6 y Bosch IoT Gateway Software 9.3.0 permite a un atacante remoto falsificar solicitudes GET a URL arbitrarias. Además, esto podría permitir que un atacante lea archivos zip confidenciales del servidor local."
    }
  ],
  "lastModified": "2026-06-17T02:13:49.910",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bosch:iot_gateway_software:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "4A0D18DA-8DAE-4EF4-BD80-CA327C872487",
              "versionEndExcluding": "9.3.0"
            },
            {
              "criteria": "cpe:2.3:a:bosch:prosyst_mbs_sdk:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "F04B3C5D-FCB9-48F5-BFA0-3673BCF23D8D",
              "versionEndExcluding": "8.2.6"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "psirt@bosch.com"
}