« Volver al listado

CVE-2019-10997

Estado: ModificadaMedia (5.9)—

An issue was discovered on Phoenix Contact AXC F 2152 (No.2404267) before 2019.0 LTS and AXC F 2152 STARTERKIT (No.1046568) before 2019.0 LTS devices. Protocol Fuzzing on PC WORX Engineer by a man in the middle attacker stops the PLC service. The device must be rebooted, or the PLC service must be restarted manually via a Linux shell.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2019-10997",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 7.1,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 6.9,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 5.9,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "HIGH",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 2.2
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2019-06-17T18:15:10.703",
  "references": [
    {
      "url": "https://dam-mdc.phoenixcontact.com/asset/156443151564/fa7be4d04c301f18c6cc0e0872193a42/Security_Advisory_AXC_F_2152_FW.pdf",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://dam-mdc.phoenixcontact.com/asset/156443151564/fa7be4d04c301f18c6cc0e0872193a42/Security_Advisory_AXC_F_2152_FW.pdf",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on Phoenix Contact AXC F 2152 (No.2404267) before 2019.0 LTS and AXC F 2152 STARTERKIT (No.1046568) before 2019.0 LTS devices. Protocol Fuzzing on PC WORX Engineer by a man in the middle attacker stops the PLC service. The device must be rebooted, or the PLC service must be restarted manually via a Linux shell."
    },
    {
      "lang": "es",
      "value": "Se descubrió un problema en el Phoenix Contact AXC F 2152 (No.2404267) antes de 2019.0 LTS y AXC F 2152 STARTERKIT (No.1046568) antes de los dispositivos 2019.0 LTS. Fuzzing de protocolo en PC WORX Ingeniero de un hombre en el atacante central detiene el servicio de PLC. El dispositivo debe reiniciarse o el servicio de PLC debe reiniciarse manualmente a través de un shell de Linux."
    }
  ],
  "lastModified": "2026-06-17T02:12:05.220",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:axc_f_2152_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "55E6AFB5-E010-46E0-9BB6-D373332705F4",
              "versionEndExcluding": "2019.0_lts"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:axc_f_2152:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "AE2E6118-6587-444A-A143-9C3A1E6ED4FD"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:axc_f_2152_starterkit_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "0540D667-F61E-4DEC-A83C-F20EF0CD882D",
              "versionEndExcluding": "2019.0_lts"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:axc_f_2152_starterkit:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "079A104B-2016-4830-80C1-3AB969106649"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}