CVE-2018-8872
Estado: ModificadaAlta (8.1)—
In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 2.25%
- Percentil entre todas las CVEs puntuadas: 82
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-119
- CWE-119
Referencias
- http://www.securityfocus.com/bid/103947
- https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02
- https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/
- http://www.securityfocus.com/bid/103947
- https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02
- https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/
JSON original (NVD)
Mostrar
{
"id": "CVE-2018-8872",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 9.3,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"authentication": "NONE",
"integrityImpact": "COMPLETE",
"accessComplexity": "MEDIUM",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 8.1,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.2
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "Schneider Electric",
"product": "Triconex Tricon",
"versions": [
{
"status": "affected",
"version": "MP model 3008 firmware versions 10.0-10.4"
}
]
}
]
}
],
"published": "2018-05-04T17:29:00.723",
"references": [
{
"url": "http://www.securityfocus.com/bid/103947",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/",
"tags": [
"Vendor Advisory"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "http://www.securityfocus.com/bid/103947",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"description": [
{
"lang": "en",
"value": "CWE-119"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-119"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory."
},
{
"lang": "es",
"value": "En Schneider Electric Triconex Tricon MP modelo 3008 con versiones de firmware 10.0-10.4, las llamadas del sistema leen directamente de las direcciones de memoria en el área del programa de control sin ningún tipo de verificación. La manipulación de estos datos podría permitir que los datos del atacante se copien en cualquier sitio de la memoria."
}
],
"lastModified": "2026-06-17T02:05:33.667",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:triconex_tricon_mp_3008_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6A170B3E-344C-45F1-BE91-803564D487E8",
"versionEndIncluding": "10.4",
"versionStartIncluding": "10.0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:triconex_tricon_mp_3008:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "1A4185CD-357B-4160-A3CC-5977590A80EF"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}