« Volver al listado

CVE-2018-7297

Estado: ModificadaCrítica (9.8)—

Remote Code Execution in the TCL script interpreter in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to obtain read/write access and execute system commands on the device. This vulnerability can be exploited by unauthenticated attackers with access to the web interface.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2018-7297",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 10,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "authentication": "NONE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2018-02-22T19:29:04.810",
  "references": [
    {
      "url": "http://atomic111.github.io/article/homematic-ccu2-remote-code-execution",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://www.exploit-db.com/exploits/44368/",
      "source": "cve@mitre.org"
    },
    {
      "url": "http://atomic111.github.io/article/homematic-ccu2-remote-code-execution",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.exploit-db.com/exploits/44368/",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Remote Code Execution in the TCL script interpreter in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to obtain read/write access and execute system commands on the device. This vulnerability can be exploited by unauthenticated attackers with access to the web interface."
    },
    {
      "lang": "es",
      "value": "Ejecución remota de código en el intérprete TCL de scripts en eQ-3 AG Homematic CCU2, en versiones 2.29.2 y anteriores, permite que atacantes remotos obtengan acceso de lectura/escritura y ejecuten comandos del sistema en el dispositivo. Esta vulnerabilidad podría ser explotada por atacantes no autenticados con acceso a la interfaz web."
    }
  ],
  "lastModified": "2026-06-17T02:02:58.323",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:eq-3:homematic_central_control_unit_ccu2_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "65FE646C-A557-4FB1-8C74-655BF6820784",
              "versionEndIncluding": "2.29.22"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:eq-3:homematic_central_control_unit_ccu2:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "250E0A8B-A3F3-4A65-9C9D-8327EB1D99E5"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}