« Volver al listado

CVE-2018-7075

Estado: ModificadaMedia (6.1)—

A remote cross-site scripting (XSS) vulnerability was identified in HPE Intelligent Management Center (iMC) PLAT version v7.3 (E0506). The vulnerability is fixed in Intelligent Management Center PLAT 7.3 E0605P04 or subsequent version.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2018-7075",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4.3,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.0",
          "baseScore": 6.1,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 2.7,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "security-alert@hpe.com",
      "affectedData": [
        {
          "vendor": "Hewlett Packard Enterprise",
          "product": "HPE Intelligent Management Center (IMC)",
          "versions": [
            {
              "status": "affected",
              "version": "v7.3 (E0506)"
            }
          ]
        }
      ]
    }
  ],
  "published": "2018-08-06T20:29:02.117",
  "references": [
    {
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf03863en_us",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "security-alert@hpe.com"
    },
    {
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf03863en_us",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote cross-site scripting (XSS) vulnerability was identified in HPE Intelligent Management Center (iMC) PLAT version v7.3 (E0506). The vulnerability is fixed in Intelligent Management Center PLAT 7.3 E0605P04 or subsequent version."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad de Cross-Site Scripting (XSS) remoto en HPE Intelligent Management Center (iMC) PLAT en versiones 7.3 (E0506). La vulnerabilidad ha sido resuelta en Intelligent Management Center PLAT 7.3 E0605P04 o siguientes."
    }
  ],
  "lastModified": "2026-06-17T02:02:37.807",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:hp:intelligent_management_center:7.3:e0506:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "394C1F2C-5852-4A99-82AD-1B874E8F4164"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com"
}