CVE-2018-5472
Estado: ModificadaCrítica (9.8)—
Philips Intellispace Portal all versions 7.0.x and 8.0.x have an insecure windows permissions vulnerability that could allow an attacker to gain unauthorized access and in some cases escalate their level of privilege or execute arbitrary code.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 4.51%
- Percentil entre todas las CVEs puntuadas: 91
- Fecha de la puntuación: 4/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-264
- NVD-CWE-noinfo
Referencias
- http://www.securityfocus.com/bid/103182
- https://ics-cert.us-cert.gov/advisories/ICSMA-18-058-02
- https://www.usa.philips.com/healthcare/about/customer-support/product-security
- http://www.securityfocus.com/bid/103182
- https://ics-cert.us-cert.gov/advisories/ICSMA-18-058-02
- https://www.usa.philips.com/healthcare/about/customer-support/product-security
JSON original (NVD)
Mostrar
{
"id": "CVE-2018-5472",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": true,
"impactScore": 6.4,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "Philips",
"product": "Philips IntelliSpace Portal",
"versions": [
{
"status": "affected",
"version": "8.0.x"
},
{
"status": "affected",
"version": "7.0.x"
}
]
}
]
}
],
"published": "2018-03-26T14:29:00.650",
"references": [
{
"url": "http://www.securityfocus.com/bid/103182",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-058-02",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security",
"tags": [
"Vendor Advisory"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "http://www.securityfocus.com/bid/103182",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-058-02",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"description": [
{
"lang": "en",
"value": "CWE-264"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Philips Intellispace Portal all versions 7.0.x and 8.0.x have an insecure windows permissions vulnerability that could allow an attacker to gain unauthorized access and in some cases escalate their level of privilege or execute arbitrary code."
},
{
"lang": "es",
"value": "Philips IntelliSpace Portal, en todas las versiones 7.0.x y 8.0.x, contiene una vulnerabilidad de permisos de Windows inseguros que podría permitir a un atacante obtener acceso no autorizado y, en algunos casos, escalar su nivel de privilegios o ejecutar código arbitrario."
}
],
"lastModified": "2026-06-17T02:00:22.627",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:philips:intellispace_portal:8.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "374B9A63-793D-41A1-A02F-4642031DA5FA"
},
{
"criteria": "cpe:2.3:a:philips:intellispace_portal:9.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "784EBE3C-D9CB-433E-BC1D-4403B3BAB6AA"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}