CVE-2018-5454
Estado: ModificadaAlta (8.1)—
Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability where code debugging methods are enabled, which could allow an attacker to remotely execute arbitrary code during runtime.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 3.43%
- Percentil entre todas las CVEs puntuadas: 89
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Impacto principal
T1203Exploitation for Client Executionexecution
Fuente: mapeo oficial MITRE CTID (CVE → ATT&CK).
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-489
- NVD-CWE-noinfo
Referencias
- http://www.securityfocus.com/bid/103182
- https://ics-cert.us-cert.gov/advisories/ICSMA-18-058-02
- https://www.usa.philips.com/healthcare/about/customer-support/product-security
- http://www.securityfocus.com/bid/103182
- https://ics-cert.us-cert.gov/advisories/ICSMA-18-058-02
- https://www.usa.philips.com/healthcare/about/customer-support/product-security
JSON original (NVD)
Mostrar
{
"id": "CVE-2018-5454",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 6.8,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "MEDIUM",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 8.1,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.2
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "Philips",
"product": "Philips IntelliSpace Portal",
"versions": [
{
"status": "affected",
"version": "8.0.x"
},
{
"status": "affected",
"version": "7.0.x"
}
]
}
]
}
],
"published": "2018-03-26T14:29:00.213",
"references": [
{
"url": "http://www.securityfocus.com/bid/103182",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-058-02",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security",
"tags": [
"Vendor Advisory"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "http://www.securityfocus.com/bid/103182",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-058-02",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"description": [
{
"lang": "en",
"value": "CWE-489"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability where code debugging methods are enabled, which could allow an attacker to remotely execute arbitrary code during runtime."
},
{
"lang": "es",
"value": "Philips IntelliSpace Portal, en todas las versiones 8.0.x y 7.0.x, contiene una vulnerabilidad por la que se habilitan métodos de depuración de código. Esto podría permitir que un atacante ejecute código arbitrario de forma remota durante el tiempo de ejecución."
}
],
"lastModified": "2026-06-17T02:00:20.803",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:philips:intellispace_portal:8.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "374B9A63-793D-41A1-A02F-4642031DA5FA"
},
{
"criteria": "cpe:2.3:a:philips:intellispace_portal:9.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "784EBE3C-D9CB-433E-BC1D-4403B3BAB6AA"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}