CVE-2018-2858
Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: HTTP data path subsystems). The supported version that is affected is Prior to 8.7.17. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks of this vulnerability can result in unauthorized read access to a subset of Sun ZFS Storage Appliance Kit (AK) accessible data. CVSS 3.0 Base Score 5.3 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
- Puntuación base: 5.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.94%
- Percentil entre todas las CVEs puntuadas: 80
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- NVD-CWE-noinfo
Referencias
- http://www.oracle.com/technetwork/security-advisory/cpuapr2018-3678067.html
- http://www.securityfocus.com/bid/103895
- http://www.securitytracker.com/id/1040702
- http://www.oracle.com/technetwork/security-advisory/cpuapr2018-3678067.html
- http://www.securityfocus.com/bid/103895
- http://www.securitytracker.com/id/1040702
JSON original (NVD)
Mostrar
{
"id": "CVE-2018-2858",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2018-2858",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-10-03T19:13:17.870823Z"
}
}
],
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 5.3,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 1.4,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "secalert_us@oracle.com",
"affectedData": [
{
"vendor": "Oracle Corporation",
"product": "Sun ZFS Storage Appliance Kit (AK) Software",
"versions": [
{
"status": "affected",
"version": "unspecified",
"lessThan": "8.7.17",
"versionType": "custom"
}
]
}
]
}
],
"published": "2018-04-19T02:29:06.817",
"references": [
{
"url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2018-3678067.html",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "secalert_us@oracle.com"
},
{
"url": "http://www.securityfocus.com/bid/103895",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "secalert_us@oracle.com"
},
{
"url": "http://www.securitytracker.com/id/1040702",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "secalert_us@oracle.com"
},
{
"url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2018-3678067.html",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.securityfocus.com/bid/103895",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.securitytracker.com/id/1040702",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: HTTP data path subsystems). The supported version that is affected is Prior to 8.7.17. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks of this vulnerability can result in unauthorized read access to a subset of Sun ZFS Storage Appliance Kit (AK) accessible data. CVSS 3.0 Base Score 5.3 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N)."
},
{
"lang": "es",
"value": "Vulnerabilidad en el componente Sun ZFS Storage Appliance Kit (AK) de Oracle Sun Systems Products Suite (subcomponente: HTTP data path subsystems). La versión compatible afectada es la anterior a la 8.7.17. Esta vulnerabilidad fácilmente explotable permite que un atacante sin autenticar con acceso en red via HTTP comprometa la seguridad de Sun ZFS Storage Appliance Kit (AK). Los ataques exitosos a esta vulnerabilidad pueden resultar en un acceso de lectura sin autorización a un subconjunto de datos accesibles de Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 5.3 (impactos en la confidencialidad). Vector CVSS: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N)."
}
],
"lastModified": "2026-06-17T01:56:30.280",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:oracle:sun_zfs_storage_appliance_kit:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "649B18EE-04E3-43BA-A46D-9146AF55E506",
"versionEndExcluding": "8.7.17"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "secalert_us@oracle.com"
}