CVE-2018-20008
Estado: ModificadaMedia (6.8)—
iBall Baton iB-WRB302N20122017 devices have improper access control over the UART interface, allowing physical attackers to discover Wi-Fi credentials (plain text) and the web-console password (base64) via the debugging console.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 6.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.29%
- Percentil entre todas las CVEs puntuadas: 20
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-312, CWE-732
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2018-20008",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 2.1,
"accessVector": "LOCAL",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "LOW",
"obtainAllPrivilege": false,
"exploitabilityScore": 3.9,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.8,
"attackVector": "PHYSICAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 0.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2019-05-28T21:29:00.327",
"references": [
{
"url": "https://payatu.com/ibaton-routers-responsible-disclosure/",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.iball.co.in/Category/Baton/283",
"tags": [
"Product",
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://payatu.com/ibaton-routers-responsible-disclosure/",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.iball.co.in/Category/Baton/283",
"tags": [
"Product",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-312"
},
{
"lang": "en",
"value": "CWE-732"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "iBall Baton iB-WRB302N20122017 devices have improper access control over the UART interface, allowing physical attackers to discover Wi-Fi credentials (plain text) and the web-console password (base64) via the debugging console."
},
{
"lang": "es",
"value": "Dispositivos iBall Baton iB-WRB302N20122017 tienen un control de acceso inadecuado sobre la interfaz UART, lo que permite a los atacantes físicos descubrir las credenciales de Wi-Fi (texto sin formato) y la contraseña de la consola Web (Base64) a través de la consola de depuración."
}
],
"lastModified": "2026-06-17T01:52:09.510",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:iball:ib-wrb302n_firmware:ib-wrb302n20122017:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BEF66D8A-4EC2-427B-9E3D-F8A997FA57C0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:iball:ib-wrb302n:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "EC5203AD-34DB-47A9-9246-D2E4082A1D1C"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}