CVE-2018-12455
Estado: ModificadaAlta (8.1)—
Intelbras NPLUG 1.0.0.14 wireless repeater devices have a critical vulnerability that allows an attacker to authenticate in the web interface just by using "admin:" as the name of a cookie.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 5.87%
- Percentil entre todas las CVEs puntuadas: 93
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-287
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2018-12455",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 9.3,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"authentication": "NONE",
"integrityImpact": "COMPLETE",
"accessComplexity": "MEDIUM",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 8.1,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.2
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2018-10-10T21:29:01.163",
"references": [
{
"url": "http://seclists.org/fulldisclosure/2018/Oct/18",
"tags": [
"Exploit",
"Mailing List",
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "http://seclists.org/fulldisclosure/2018/Oct/18",
"tags": [
"Exploit",
"Mailing List",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Intelbras NPLUG 1.0.0.14 wireless repeater devices have a critical vulnerability that allows an attacker to authenticate in the web interface just by using \"admin:\" as the name of a cookie."
},
{
"lang": "es",
"value": "Los dispositivos de repetidores inalámbricos Intelbras NPLUG 1.0.0.14 tienen una vulnerabilidad crítica que permite que un atacante se autentique en la interfaz web solo empleando \"admin:\" como nombre de la cookie."
}
],
"lastModified": "2026-06-17T01:37:48.640",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:intelbras:nplug_firmware:1.0.0.14:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F57C7CE2-0811-440F-84A8-7A3988CB7942"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:intelbras:nplug:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "31AF436F-BAAA-4656-89C7-E63A62C1A7A0"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}