CVE-2018-12338
Estado: ModificadaCrítica (9.8)—
Undocumented Factory Backdoor in ECOS System Management Appliance (aka SMA) 5.2.68 allows the vendor to extract confidential information and manipulate security relevant configurations via remote root SSH access.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.54%
- Percentil entre todas las CVEs puntuadas: 74
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- NVD-CWE-noinfo
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2018-12338",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 10,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"authentication": "NONE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2018-06-17T16:29:00.817",
"references": [
{
"url": "https://telematik.prakinf.tu-ilmenau.de/ecos-sbs/advisory.html",
"tags": [
"Mitigation",
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://telematik.prakinf.tu-ilmenau.de/ecos-sbs/advisory.html",
"tags": [
"Mitigation",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Undocumented Factory Backdoor in ECOS System Management Appliance (aka SMA) 5.2.68 allows the vendor to extract confidential information and manipulate security relevant configurations via remote root SSH access."
},
{
"lang": "es",
"value": "Backdoor de fábrica sin documentar en ECOS System Management Appliance (también conocido como SMA) 5.2.68 permite que el fabricante extraiga información confidencial y manipule configuraciones relevantes para la seguridad mediante acceso SSH root remoto."
}
],
"lastModified": "2026-06-17T01:37:35.400",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:ecos:system_management_appliance:5.2.68:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8EF739BB-C608-4F11-ACEB-DFEEA38F7EF4"
}
],
"operator": "OR"
}
]
}
],