CVE-2018-11463

Estado: ModificadaAlta (7.8)—

A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A buffer overflow in the service command application could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction.

Leer descripción completaMostrar menos

The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (5)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2018-11463",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4.6,
          "accessVector": "LOCAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 3.9,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens AG",
          "product": "SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8",
          "versions": [
            {
              "status": "affected",
              "version": "SINUMERIK 808D V4.7 : All versions"
            },
            {
              "status": "affected",
              "version": "SINUMERIK 808D V4.8 : All versions"
            },
            {
              "status": "affected",
              "version": "SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1"
            },
            {
              "status": "affected",
              "version": "SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5"
            },
            {
              "status": "affected",
              "version": "SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3"
            }
          ]
        }
      ]
    }
  ],
  "published": "2018-12-12T16:29:00.543",
  "references": [
    {
      "url": "http://www.securityfocus.com/bid/106185",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "http://www.securityfocus.com/bid/106185",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A buffer overflow in the service command application could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SINUMERIK 808D V4.7 (todas las versiones), SINUMERIK 808D V4.8 (todas las versiones), SINUMERIK 828D V4.7 (todas las versiones anteriores a la V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (todas las versiones anteriores a la V4.7 SP6 HF5) y SINUMERIK 840D sl V4.8 (todas las versiones anteriores a la V4.8 SP3). Un desbordamiento de búfer en la aplicación de comandos del servicio podría permitir que un atacante local ejecute código con privilegios elevados. Esta vulnerabilidad de seguridad podría ser explotada por atacantes con acceso local al sistema afectado. Su explotación con éxito requiere privilegios de usuario, pero no requiere interacción del usuario. Esta vulnerabilidad podría permitir que un atacante comprometa la confidencialidad, integridad y disponibilidad del sistema. En el momento de la publicación del advisory, no se conoce ninguna explotación pública de la vulnerabilidad de seguridad."
    }
  ],
  "lastModified": "2026-06-17T01:35:59.407",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_808d_v4.7_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "C3A4ADF0-33D6-49AA-9F17-594FB2405188"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_808d_v4.7:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "C5B5C872-3E63-4696-BCEB-A4D236EC2B09"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_808d_v4.8_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "9A6EFCCC-87AB-4E71-93D7-206EF6E57AE8"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_808d_v4.8:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "728CA45F-CE23-4EB8-810F-5292ACFD3D62"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_828d_v4.7_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "96A87A16-2670-4751-8B62-9C7ACE6BC705",
              "versionEndIncluding": "4.7"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_828d_v4.7:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "B5F8425A-13F1-404C-9BF2-E9259BFE9BED"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_v4.7_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "061BC154-7411-4982-B9F8-9A1873099EC5",
              "versionEndIncluding": "4.7"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_840d_sl_v4.7:*:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "40B6E241-2FA0-45E0-B64D-F7F41746FF78"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_v4.8_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "C4E14591-E3AA-4177-814E-3FB4C8F15590",
              "versionEndIncluding": "4.8"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_840d_sl_v4.8:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "1F75930F-4085-4A41-BCB6-930ADB8F0C32"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}