CVE-2018-11400
Estado: ModificadaMedia (4.6)—
In SimpliSafe Original, the Base Station fails to detect tamper attempts: it does not send a notification if a physically proximate attacker removes the battery and external power.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Puntuación base: 4.6
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.31%
- Percentil entre todas las CVEs puntuadas: 22
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- NVD-CWE-noinfo
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2018-11400",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 4.9,
"accessVector": "LOCAL",
"vectorString": "AV:L/AC:L/Au:N/C:N/I:N/A:C",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "NONE"
},
"acInsufInfo": true,
"impactScore": 6.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 3.9,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 4.6,
"attackVector": "PHYSICAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 0.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2018-05-24T05:29:00.303",
"references": [
{
"url": "https://simplisafe.com/files/pdf/SimpliSafe_advisory_8-17-18.pdf",
"source": "cve@mitre.org"
},
{
"url": "https://www.simpleorsecure.net/simplisafe-security-advisory/",
"tags": [
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://simplisafe.com/files/pdf/SimpliSafe_advisory_8-17-18.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.simpleorsecure.net/simplisafe-security-advisory/",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In SimpliSafe Original, the Base Station fails to detect tamper attempts: it does not send a notification if a physically proximate attacker removes the battery and external power."
},
{
"lang": "es",
"value": "Cross-Site Scripting (XSS) persistente e inyección HTML no persistente en HP Network Operations Management Ultimate, versiones 2017.07, 2017.11 y 2018.02 y en Network Automation, versiones 10.00, 10.10, 10.11, 10.20, 10.30, 10.40 y 10.50. La vulnerabilidad podría explotarse remotamente para permitir Cross-Site Scripting (XSS) persistente y una inyección HTML no persistente."
}
],
"lastModified": "2026-06-17T01:35:51.393",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:simplisafe:u9k-bs1000_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "729EED11-09BA-4C04-965A-8090C90B6D6C"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:simplisafe:u9k-bs1000:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "CC06CDD3-4BE5-4437-AB2D-6CCCF5F776FB"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}