CVE-2018-11240
Estado: ModificadaCrítica (9.8)—
An issue was discovered on SoftCase T-Router build 20112017 devices. There are no restrictions on the 'exec command' feature of the T-Router protocol. If the command syntax is correct, there is code execution both on the other modem and on the main servers. This is fixed in production builds as of Spring 2018.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 2.29%
- Percentil entre todas las CVEs puntuadas: 83
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-732
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2018-11240",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 10,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"authentication": "NONE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2018-09-21T15:29:00.327",
"references": [
{
"url": "https://gist.github.com/neolead/1b90d8df7ef4fd1d3d03c1265e5804ac#file-cve-2018-11240-txt",
"tags": [
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://gist.github.com/neolead/1b90d8df7ef4fd1d3d03c1265e5804ac#file-cve-2018-11240-txt",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-732"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on SoftCase T-Router build 20112017 devices. There are no restrictions on the 'exec command' feature of the T-Router protocol. If the command syntax is correct, there is code execution both on the other modem and on the main servers. This is fixed in production builds as of Spring 2018."
},
{
"lang": "es",
"value": "Se ha descubierto un error en la build 20112017 de los dispositivos SoftCase T-Router. No existen restricciones en la característica \"exec command\" en el protocolo T-Router. Si la sintaxis del comando es correcta, existe ejecución de código tanto en el otro módem como en los principales servidores. Esto está resuelto en las builds producidas desde primavera de 2018."
}
],
"lastModified": "2026-06-17T01:35:33.773",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:softcase:t-router_firmware:20112017:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "CF841993-3A11-4506-B493-ADC2E9A69A54"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:softcase:t-router:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "63E3B8CA-D711-465B-BCA5-B1FD400986B9"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}