CVE-2018-10635
Estado: ModificadaCrítica (9.8)—
In Universal Robots Robot Controllers Version CB 3.1, SW Version 3.4.5-100, ports 30001/TCP to 30003/TCP listen for arbitrary URScript code and execute the code. This enables a remote attacker who has access to the ports to remotely execute code that may allow root access to be obtained.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 5.08%
- Percentil entre todas las CVEs puntuadas: 92
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-306
- CWE-306
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2018-10635",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 10,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"authentication": "NONE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "Universal Robots",
"product": "Universal Robots Robot Controllers Version CB 3.1, SW Version 3.4.5-100",
"versions": [
{
"status": "affected",
"version": "Universal Robots Robot Controllers Version CB 3.1, SW Version 3.4.5-100"
}
]
}
]
}
],
"published": "2018-07-11T17:29:00.320",
"references": [
{
"url": "http://www.securityfocus.com/bid/104710",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-191-01",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "http://www.securityfocus.com/bid/104710",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-191-01",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"description": [
{
"lang": "en",
"value": "CWE-306"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-306"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In Universal Robots Robot Controllers Version CB 3.1, SW Version 3.4.5-100, ports 30001/TCP to 30003/TCP listen for arbitrary URScript code and execute the code. This enables a remote attacker who has access to the ports to remotely execute code that may allow root access to be obtained."
},
{
"lang": "es",
"value": "En Universal Robots Robot Controllers en versión CB 3.1, software en versión 3.4.5-100, los puertos 30001/TCP hasta el 30003/TCP escuchan en busca de código URScript arbitrario y lo ejecutan. Esto permite que un atacante remoto con acceso a los puertos ejecute código de forma remota para poder obtener acceso root."
}
],
"lastModified": "2026-06-17T01:34:19.653",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:universal-robots:cb3.1_firmware:3.4.5-100:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7DBF23CE-E61B-4EDF-80D5-261F901CA957"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:universal-robots:cb3.1:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "6646769C-25A1-4558-A229-62AF8B1FE167"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"vendorComments": [
{
"comment": "Software version 5.10 brings improvements to usability and configurability of Secure Shell Protocol (SSH), such that tunneling can be used to secure primary, secondary, RT, RTDE, DashBoard server and other interfaces. Universal Robots recommends that all users use SSH tunneling to access these interfaces in applications requiring authentication and encryption.\n\nAdditionally, SW version 5.10 includes a built-in configurable firewall, allowing fine-grained restrictions of remote access, and number of other security improvements. Universal Robots (UR) recommends always using the latest UR software, as security improvements will be rolled out continuously.\n\nCB2 and CB3 cobots are designed to be operating in factory networks where security relies on boundary protection (firewalls) and trusted clients on the network. They must only be connected to trusted networks and operated by authorized personnel.\n",
"lastModified": "2022-04-12T13:43:22.727",
"organization": "Universal Robots"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}