CVE-2018-10607
Estado: ModificadaAlta (7.5)—
Martem TELEM GW6 and GWM devices with firmware 2018.04.18-linux_4-01-601cb47 and prior allow the creation of new connections to one or more IOAs, without closing them properly, which may cause a denial of service within the industrial process control channel.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 3.16%
- Percentil entre todas las CVEs puntuadas: 88
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-400
- CWE-400
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2018-10607",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "Martem",
"product": "TELEM GW6",
"versions": [
{
"status": "affected",
"version": "2018.04.18-linux_4-01-601cb47 and prior"
}
]
},
{
"vendor": "Martem",
"product": "TELEM GWM",
"versions": [
{
"status": "affected",
"version": "2018.04.18-linux_4-01-601cb47 and prior"
}
]
}
]
}
],
"published": "2018-07-31T17:29:00.327",
"references": [
{
"url": "http://martem.eu/csa/Martem_CSA_Telem_1805184.pdf",
"tags": [
"Vendor Advisory"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "http://www.securityfocus.com/bid/104286",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-142-01",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "http://martem.eu/csa/Martem_CSA_Telem_1805184.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.securityfocus.com/bid/104286",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-142-01",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"description": [
{
"lang": "en",
"value": "CWE-400"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-400"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Martem TELEM GW6 and GWM devices with firmware 2018.04.18-linux_4-01-601cb47 and prior allow the creation of new connections to one or more IOAs, without closing them properly, which may cause a denial of service within the industrial process control channel."
},
{
"lang": "es",
"value": "Los dispositivos Martem TELEM GW6 y GWM con firmware 2018.04.18-linux_4-01-601cb47 y anteriores permiten la creación de nuevas conexiones a una o más IOA sin cerrarlas correctamente, lo que podría provocar una denegación de servicio (DoS) en el canal de control del proceso industrial."
}
],
"lastModified": "2026-06-17T01:34:16.097",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:martem:telem-gwm_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1F842EC5-BB59-4B76-9F62-0B0C7A298FB1",
"versionEndIncluding": "2018.04.18-linux_4-01-601cb47"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:martem:telem-gwm:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "B3956ED9-4DA6-4E06-9D73-8B39AC053D62"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:martem:telem-gw6_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7AA09E71-BFB2-45BE-A01E-56B54EC4A1D4",
"versionEndIncluding": "2018.04.18-linux_4-01-601cb47"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:martem:telem-gw6:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "98A43B49-F6FB-4B74-A1DB-3F45309256C8"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}