« Volver al listado

CVE-2018-10601

Estado: ModificadaAlta (8.2)—

IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that exposes an "echo" service, in which an attacker-sent buffer to an attacker-chosen device address within the same subnet is copied to the stack with no boundary checks, hence resulting in stack overflow.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (18)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2018-10601",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 5.4,
          "accessVector": "ADJACENT_NETWORK",
          "vectorString": "AV:A/AC:M/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 5.5,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 8.2,
          "attackVector": "ADJACENT_NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:L/A:H",
          "integrityImpact": "LOW",
          "userInteraction": "NONE",
          "attackComplexity": "HIGH",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 1.6
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "ICS-CERT",
          "product": "IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors",
          "versions": [
            {
              "status": "affected",
              "version": "The following IntelliVue Patient Monitors versions are affected: IntelliVue Patient Monitors MP Series (includingMP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, and IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only). The following Avalon Fetal/Maternal Monitors versions are affected: Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3"
            }
          ]
        }
      ]
    }
  ],
  "published": "2018-06-05T20:29:00.903",
  "references": [
    {
      "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "ics-cert@hq.dhs.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that exposes an \"echo\" service, in which an attacker-sent buffer to an attacker-chosen device address within the same subnet is copied to the stack with no boundary checks, hence resulting in stack overflow."
    },
    {
      "lang": "es",
      "value": "IntelliVue Patient Monitors MP Series (incluyendo MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M y (X3/MX100 solo para Rev M) y Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 con software en Revisions F.0, G.0 y J.3 tienen una vulnerabilidad que expone un servicio \"echo\" por el cual un búfer enviado por el atacante a una dirección de dispositivo en la misma subred elegida por el atacante se copia a la pila sin comprobaciones de límites, lo que resulta en un desbordamiento de pila."
    }
  ],
  "lastModified": "2026-06-17T01:34:15.347",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mp2_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D4DC680B-B8F8-4FAA-B4C3-D36003BDDCCA"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mp2:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "C9178E4C-8965-496C-9FF7-1DF87371DC48"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_x2_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E42604C2-7CB6-42AC-9272-CFABFC4DC85A"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_x2:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "29626D40-46F7-485F-A700-070424820F16"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mp30_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "314F12E4-D613-43C4-9B14-5FC9F598AD55"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mp30:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "E089B9E5-8B28-4DBA-A5D0-B6BBB7D5F3E8"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mp50_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8EE71984-367F-428F-AD0E-D168F76A2002"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mp50:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "7216177F-179D-451E-ABC3-C1843AF0D35F"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mp70_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "41A04EC9-FAC7-4C36-8E95-4BDC1E0702FB"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mp70:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "3F608D38-1096-41F9-9EB5-854C79068144"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_np90_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "4A47C624-AF39-4BE2-9484-54A5E51A784B"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_np90:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "C202FA49-1CC4-46E6-AA11-3EAB17008AA2"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx700_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "43C2466F-A371-4386-B098-F724D5CD14CB"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx700:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "DDF21FA3-9650-442F-8E13-281A9975C47B"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx800_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E9C6A5F3-C845-4561-A451-DC3C966E8D8C"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx800:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "C38B732B-8629-40FE-A333-E69A7F2CFB18"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx400_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "58F21718-A0DE-419E-B82D-447ADC337E30"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx400:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "27B8D0E2-316A-45E5-8FC1-AE70F07DB7FA"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx450_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "C337EAF0-41E9-4BF3-8483-6FC74EA93B5A"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx450:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "E73CF245-4519-4F35-A5EE-74981E0BDB9F"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx500_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E119897D-9FB5-461C-8463-EBA3CFC87855"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx500:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "B0CEB056-7422-4E4E-86A5-D58311129788"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx550_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6D72DF93-DF02-411D-80BE-85286F553B1E"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx550:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "8B03E7D9-01DC-492F-BA52-9165E78BE498"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_x3_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "708EB7F4-9747-4B0C-937D-F1ED07300FAE"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_x3:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "F68AF067-6802-40E7-9D34-03D83D9F3E77"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx100_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8D7C4F77-6005-4AAA-83CA-CA9F60043A7A"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx100:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "0D2A5BBF-C360-4281-AD34-C0941831DA64"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:avalon_fetal\\/maternal_monitors_fm20_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "F3834798-6741-4274-B5C5-0CA2C13A7B12"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:avalon_fetal\\/maternal_monitors_fm20:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "3A418F05-18B3-405E-A62C-4D9677C297DB"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:avalon_fetal\\/maternal_monitors_fm30_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "5634CF44-3593-4D58-8B72-D3DA253530F8"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:avalon_fetal\\/maternal_monitors_fm30:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "6C74CF2F-501F-4D18-82C7-4D25D42905E7"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:avalon_fetal\\/maternal_monitors_fm40_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "55DCC271-9428-4A34-B2C8-DA3CCB74D2DD"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:avalon_fetal\\/maternal_monitors_fm40:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "6FD8C562-C918-47DF-AFEB-4CFA53DE3D22"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:avalon_fetal\\/maternal_monitors_fm50_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "0AB9A60A-D567-4B7A-A73A-AA566CAD739A"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:avalon_fetal\\/maternal_monitors_fm50:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "9D192DA1-C9F4-4666-B0E3-6B0529E3BF3B"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}