CVE-2018-10576
Estado: ModificadaAlta (7.8)—
An issue was discovered on WatchGuard AP100, AP102, and AP200 devices with firmware before 1.2.9.15. Improper authentication handling by the native Access Point web UI allows authentication using a local system account (instead of the dedicated web-only user).
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.50%
- Percentil entre todas las CVEs puntuadas: 73
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (3)
CWE
- CWE-287
Referencias
- http://seclists.org/fulldisclosure/2018/May/12
- https://watchguardsupport.secure.force.com/publicKB?type=KBSecurityIssues&SFDCID=kA62A0000000LIy
- https://www.exploit-db.com/exploits/45409/
- https://www.watchguard.com/wgrd-blog/new-firmware-available-ap100ap102ap200ap300-security-vulnerability-fixes
- http://seclists.org/fulldisclosure/2018/May/12
- https://watchguardsupport.secure.force.com/publicKB?type=KBSecurityIssues&SFDCID=kA62A0000000LIy
- https://www.exploit-db.com/exploits/45409/
- https://www.watchguard.com/wgrd-blog/new-firmware-available-ap100ap102ap200ap300-security-vulnerability-fixes
JSON original (NVD)
Mostrar
{
"id": "CVE-2018-10576",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 4.6,
"accessVector": "LOCAL",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": true,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 3.9,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2018-04-30T22:29:00.373",
"references": [
{
"url": "http://seclists.org/fulldisclosure/2018/May/12",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://watchguardsupport.secure.force.com/publicKB?type=KBSecurityIssues&SFDCID=kA62A0000000LIy",
"tags": [
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.exploit-db.com/exploits/45409/",
"source": "cve@mitre.org"
},
{
"url": "https://www.watchguard.com/wgrd-blog/new-firmware-available-ap100ap102ap200ap300-security-vulnerability-fixes",
"tags": [
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "http://seclists.org/fulldisclosure/2018/May/12",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://watchguardsupport.secure.force.com/publicKB?type=KBSecurityIssues&SFDCID=kA62A0000000LIy",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.exploit-db.com/exploits/45409/",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.watchguard.com/wgrd-blog/new-firmware-available-ap100ap102ap200ap300-security-vulnerability-fixes",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on WatchGuard AP100, AP102, and AP200 devices with firmware before 1.2.9.15. Improper authentication handling by the native Access Point web UI allows authentication using a local system account (instead of the dedicated web-only user)."
},
{
"lang": "es",
"value": "Se ha descubierto un problema en los dispositivos WatchGuard AP100, AP102 y AP200 con firmware en versiones anteriores a la 1.2.9.15. La gestión de autenticación incorrecta por parte de la interfaz web de usuario de Access Point permite la autenticación por medio de una cuenta del sistema local (en lugar de un usuario dedicado exclusivo de la web)."
}
],
"lastModified": "2026-06-17T01:34:12.340",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:watchguard:ap200_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "263A0D62-FCC4-4374-8E2F-1393140D68B0",
"versionEndExcluding": "1.2.9.15"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:watchguard:ap200:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "5C6FA1D0-016C-4B73-9BC4-83848A1A6D04"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:watchguard:ap102_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FA60491C-1B5B-4E23-B27D-4285E3F71E99",
"versionEndExcluding": "1.2.9.15"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:watchguard:ap102:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "6E009741-C76C-49F3-83A4-4BB17D1A9510"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:watchguard:ap100_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "428B2A59-5F74-4685-B6A9-F0CC9AFEE949",
"versionEndExcluding": "1.2.9.15"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:watchguard:ap100:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "8379C407-E7DC-4193-9BD0-5BAE24E637B8"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}