CVE-2017-9969

Estado: ModificadaMedia (6.7)—

An information disclosure vulnerability exists in Schneider Electric's IGSS Mobile application version 3.01 and prior. Passwords are stored in clear text in the configuration which can result in exposure of sensitive information.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2017-9969",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 2.1,
          "accessVector": "LOCAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "LOW",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 3.9,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 6.7,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 0.8
      }
    ]
  },
  "affected": [
    {
      "source": "cybersecurity@se.com",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2018-02-12T23:29:00.403",
  "references": [
    {
      "url": "http://www.securityfocus.com/bid/103046",
      "tags": [
        "Third Party Advisory",
        "VDB Entry",
        "Vendor Advisory"
      ],
      "source": "cybersecurity@se.com"
    },
    {
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-046-03",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "cybersecurity@se.com"
    },
    {
      "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-039-02/",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "cybersecurity@se.com"
    },
    {
      "url": "http://www.securityfocus.com/bid/103046",
      "tags": [
        "Third Party Advisory",
        "VDB Entry",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-046-03",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-039-02/",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-522"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An information disclosure vulnerability exists in Schneider Electric's IGSS Mobile application version 3.01 and prior. Passwords are stored in clear text in the configuration which can result in exposure of sensitive information."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad de divulgación de información en la aplicación Schneider Electric's IGSS Mobile, en versiones 3.01 y anteriores. Las contraseñas se almacenan en texto claro en la configuración, lo que puede resultar en la exposición de información sensible."
    }
  ],
  "lastModified": "2026-06-17T01:29:18.417",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider-electric:igss_mobile:*:*:*:*:*:android:*:*",
              "vulnerable": true,
              "matchCriteriaId": "813AC34A-B612-4B5F-A372-2F3EED3E3129",
              "versionEndIncluding": "3.01"
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:igss_mobile:*:*:*:*:*:iphone_os:*:*",
              "vulnerable": true,
              "matchCriteriaId": "EDF8B4C6-943B-426A-A53A-D1E41A1C596F",
              "versionEndIncluding": "3.01"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com"
}