CVE-2017-9384
An issue was discovered on Vera VeraEdge 1.7.19 and Veralite 1.7.481 devices. The device provides a web user interface that allows a user to manage the device. As a part of the functionality the device firmware file contains a file known as relay.sh which allows the device to create relay ports and connect the device to Vera servers. This is primarily used as a method of communication between the device and Vera servers so the devices can be communicated with even when the user is not at home. One of the parameters retrieved by this specific script is "remote_host".
Leer descripción completaMostrar menos
This parameter is not sanitized by the script correctly and is passed in a call to "eval" to execute another script where remote_host is concatenated to be passed a parameter to the second script. This allows an attacker to escape from the executed command and then execute any commands of his/her choice.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 3.56%
- Percentil entre todas las CVEs puntuadas: 89
- Fecha de la puntuación: 3/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-77
Referencias
- http://packetstormsecurity.com/files/153242/Veralite-Veraedge-Router-XSS-Command-Injection-CSRF-Traversal.html
- https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Vera_sec_issues.pdf
- https://seclists.org/bugtraq/2019/Jun/8
- http://packetstormsecurity.com/files/153242/Veralite-Veraedge-Router-XSS-Command-Injection-CSRF-Traversal.html
- https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Vera_sec_issues.pdf
- https://seclists.org/bugtraq/2019/Jun/8
JSON original (NVD)
Mostrar
{
"id": "CVE-2017-9384",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 9,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"authentication": "SINGLE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2019-06-17T18:15:10.627",
"references": [
{
"url": "http://packetstormsecurity.com/files/153242/Veralite-Veraedge-Router-XSS-Command-Injection-CSRF-Traversal.html",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cve@mitre.org"
},
{
"url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Vera_sec_issues.pdf",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://seclists.org/bugtraq/2019/Jun/8",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "http://packetstormsecurity.com/files/153242/Veralite-Veraedge-Router-XSS-Command-Injection-CSRF-Traversal.html",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Vera_sec_issues.pdf",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://seclists.org/bugtraq/2019/Jun/8",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Vera VeraEdge 1.7.19 and Veralite 1.7.481 devices. The device provides a web user interface that allows a user to manage the device. As a part of the functionality the device firmware file contains a file known as relay.sh which allows the device to create relay ports and connect the device to Vera servers. This is primarily used as a method of communication between the device and Vera servers so the devices can be communicated with even when the user is not at home. One of the parameters retrieved by this specific script is \"remote_host\". This parameter is not sanitized by the script correctly and is passed in a call to \"eval\" to execute another script where remote_host is concatenated to be passed a parameter to the second script. This allows an attacker to escape from the executed command and then execute any commands of his/her choice."
},
{
"lang": "es",
"value": "Se descubrió un problema en los dispositivos Vera VeraEdge 1.7.19 y Veralite 1.7.481. El dispositivo proporciona una interfaz de usuario web que permite a un usuario administrar el dispositivo. Como parte de la funcionalidad, el archivo de firmware del dispositivo contiene un archivo conocido como relay.sh que permite al dispositivo crear puertos de retransmisión y conectar el dispositivo a los servidores Vera. Esto se usa principalmente como un método de comunicación entre el dispositivo y los servidores de Vera para que los dispositivos puedan comunicarse incluso cuando el usuario no está en casa. Uno de los parámetros recuperados por este script específico es \"remote_host\". Este parámetro no está correctamente saneado por la secuencia de comandos y se pasa en una llamada a \"eval\" para ejecutar otra secuencia de comandos donde se concatena remote_host para pasar un parámetro a la segunda secuencia de comandos. Esto permite a un atacante escapar del comando ejecutado y luego ejecutar cualquier comando de su elección."
}
],
"lastModified": "2026-06-17T01:28:00.620",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:getvera:veraedge_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "49C1D79D-A586-4D41-A10C-1815E6E0D765",
"versionEndIncluding": "1.7.19"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:getvera:veraedge:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "0A3D3CAC-84A4-4F14-8FB6-1E6437F8D2C0"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:getvera:veralite_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "AC96E7A8-DB6C-47C8-9B33-AE4ED418C70E",
"versionEndIncluding": "1.7.481"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:getvera:veralite:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "914728A7-7BA3-4612-A6AA-172B24431947"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}