« Volver al listado

CVE-2017-8417

Estado: ModificadaAlta (8.8)—

An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The device requires that a user logging into the device provide a username and password. However, the device allows D-Link apps on the mobile devices and desktop to communicate with the device without any authentication. As a part of that communication, the device uses custom version of base64 encoding to pass data back and forth between the apps and the device.

Leer descripción completaMostrar menos

However, the same form of communication can be initiated by any process including an attacker process on the mobile phone or the desktop and this allows a third party to retrieve the device's password without any authentication by sending just 1 UDP packet with custom base64 encoding. The severity of this attack is enlarged by the fact that there more than 100,000 D-Link devices out there.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2017-8417",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 3.3,
          "accessVector": "ADJACENT_NETWORK",
          "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "LOW",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 6.5,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "ADJACENT_NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2019-07-02T21:15:10.633",
  "references": [
    {
      "url": "http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Dlink_DCS_1130_security.pdf",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://seclists.org/bugtraq/2019/Jun/8",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Dlink_DCS_1130_security.pdf",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://seclists.org/bugtraq/2019/Jun/8",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-255"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The device requires that a user logging into the device provide a username and password. However, the device allows D-Link apps on the mobile devices and desktop to communicate with the device without any authentication. As a part of that communication, the device uses custom version of base64 encoding to pass data back and forth between the apps and the device. However, the same form of communication can be initiated by any process including an attacker process on the mobile phone or the desktop and this allows a third party to retrieve the device's password without any authentication by sending just 1 UDP packet with custom base64 encoding. The severity of this attack is enlarged by the fact that there more than 100,000 D-Link devices out there."
    },
    {
      "lang": "es",
      "value": "Se detectó un problema en los dispositivos DCS-1100 y DCS-1130 de D-Link. El dispositivo requiere que un usuario que inicie sesión en el dispositivo suministre un nombre de usuario y contraseña. Sin embargo, el dispositivo permite que las aplicaciones D-Link en los dispositivos móviles y de escritorio se comuniquen con el dispositivo sin ninguna autenticación. Como parte de esa comunicación, el dispositivo utiliza una versión personalizada de la codificación base64 para pasar datos en ambos sentidos entre las aplicaciones y el dispositivo. Sin embargo, la misma forma de comunicación puede iniciarse mediante cualquier proceso, incluido un proceso de atacante en el teléfono móvil o el escritorio, lo que permite a un tercero recuperar la contraseña del dispositivo sin ninguna autenticación mediante el envío de solo 1 paquete UDP con codificación base64 personalizada. La severidad de este ataque se incrementa por el hecho de que hay más de 100.000 dispositivos D-Link instalados."
    }
  ],
  "lastModified": "2026-06-17T01:26:21.393",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dcs-1100_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "554817F7-7E3D-4D69-90AC-46D86056143B"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dcs-1100:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "704F9608-72CE-49C0-B7D2-F2FE84DF0C74"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dcs-1130_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "0DB53465-4FE2-43EF-B2C6-839DFEA80D62"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dcs-1130:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "33A388EC-275D-4180-83E2-AD73F7EEB54F"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}