CVE-2017-8414
Estado: ModificadaAlta (7.8)—
An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The binary orthrus in /sbin folder of the device handles all the UPnP connections received by the device. It seems that the binary performs a sprintf operation at address 0x0000A3E4 with the value in the command line parameter "-f" and stores it on the stack. Since there is no length check, this results in corrupting the registers for the function sub_A098 which results in memory corruption.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.68%
- Percentil entre todas las CVEs puntuadas: 76
- Fecha de la puntuación: 4/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-119
Referencias
- http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html
- https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Dlink_DCS_1130_security.pdf
- https://seclists.org/bugtraq/2019/Jun/8
- http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html
- https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Dlink_DCS_1130_security.pdf
- https://seclists.org/bugtraq/2019/Jun/8
JSON original (NVD)
Mostrar
{
"id": "CVE-2017-8414",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.2,
"accessVector": "LOCAL",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"authentication": "NONE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 3.9,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2019-07-02T20:15:11.200",
"references": [
{
"url": "http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cve@mitre.org"
},
{
"url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Dlink_DCS_1130_security.pdf",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://seclists.org/bugtraq/2019/Jun/8",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Dlink_DCS_1130_security.pdf",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://seclists.org/bugtraq/2019/Jun/8",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-119"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The binary orthrus in /sbin folder of the device handles all the UPnP connections received by the device. It seems that the binary performs a sprintf operation at address 0x0000A3E4 with the value in the command line parameter \"-f\" and stores it on the stack. Since there is no length check, this results in corrupting the registers for the function sub_A098 which results in memory corruption."
},
{
"lang": "es",
"value": "Se detectó un problema en los dispositivos DCS-1100 y DCS-1130 de D-Link. El orthrus binario en la carpeta /sbin del dispositivo maneja todas las conexiones UPnP recibidas por el mismo. Al parecer el binario realiza una operación sprintf en la dirección 0x0000A3E4 con el valor en el parámetro de línea de comando \"-f\" y lo almacena en la pila. En vista de que no hay una comprobación de longitud, esto resulta en una corrupción de los registros para la función sub_A098, que resulta en una corrupción de la memoria."
}
],
"lastModified": "2026-06-17T01:26:21.013",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dlink:dcs-1100_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "554817F7-7E3D-4D69-90AC-46D86056143B"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dlink:dcs-1100:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "704F9608-72CE-49C0-B7D2-F2FE84DF0C74"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dlink:dcs-1130_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0DB53465-4FE2-43EF-B2C6-839DFEA80D62"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dlink:dcs-1130:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "33A388EC-275D-4180-83E2-AD73F7EEB54F"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}