CVE-2017-7970
Estado: ModificadaMedia (6.5)—
A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to specify Arbitrary Server Target Nodes in connection requests to the Secure Gateway and Server components.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- Puntuación base: 6.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.56%
- Percentil entre todas las CVEs puntuadas: 45
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- NVD-CWE-noinfo
Referencias
- http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/
- http://www.securityfocus.com/bid/99913
- https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere
- http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/
- http://www.securityfocus.com/bid/99913
- https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere
JSON original (NVD)
Mostrar
{
"id": "CVE-2017-7970",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 3.3,
"accessVector": "ADJACENT_NETWORK",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "LOW",
"obtainAllPrivilege": false,
"exploitabilityScore": 6.5,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 6.5,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "Schneider Electric SE",
"product": "PowerSCADA Anywhere",
"versions": [
{
"status": "affected",
"version": "Version 1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2"
}
]
},
{
"vendor": "Schneider Electric SE",
"product": "Citect Anywhere",
"versions": [
{
"status": "affected",
"version": "version 1.0"
}
]
}
]
}
],
"published": "2017-09-26T01:29:03.537",
"references": [
{
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
},
{
"url": "http://www.securityfocus.com/bid/99913",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cybersecurity@se.com"
},
{
"url": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere",
"tags": [
"Issue Tracking",
"Mitigation",
"Patch",
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
},
{
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.securityfocus.com/bid/99913",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere",
"tags": [
"Issue Tracking",
"Mitigation",
"Patch",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to specify Arbitrary Server Target Nodes in connection requests to the Secure Gateway and Server components."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad en la versión 1.0 de PowerSCADA Anywhere de Schneider Electric redistribuida con PowerSCADA Expert 8.1, PowerSCADA Expert 8.2 y Citect Anywhere 1.0 que permite que se especifiquen nodos de destino del servidor arbitrarios en peticiones de conexión a los componentes de Secure Gateway y Server."
}
],
"lastModified": "2026-06-17T01:25:34.027",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:powerscada_anywhere:1.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6445511E-70B8-4E03-A178-FFDBE02E1609"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:powerscada_expert:8.1:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "AE171A71-B1AF-471B-9D27-07D4491D05B3"
},
{
"criteria": "cpe:2.3:a:schneider-electric:powerscada_expert:8.2:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D2A3FA74-D201-41AA-BDA1-82816813AD11"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:citect_anywhere:1.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5182F21D-1DF5-492A-9A3D-B913AC6B12F6"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cybersecurity@se.com"
}