CVE-2017-6868
Estado: ModificadaAlta (8.1)—
An Improper Authentication issue was discovered in Siemens SIMATIC CP 44x-1 RNA, all versions prior to 1.4.1. An unauthenticated remote attacker may be able to perform administrative actions on the Communication Process (CP) of the RNA series module, if network access to Port 102/TCP is available and the configuration file for the CP is stored on the RNA's CPU.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 4.17%
- Percentil entre todas las CVEs puntuadas: 91
- Fecha de la puntuación: 7/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-287
- CWE-287
Referencias
- http://www.securityfocus.com/bid/99234
- http://www.securitytracker.com/id/1038788
- https://ics-cert.us-cert.gov/advisories/ICSA-17-173-01
- https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-126840.pdf
- http://www.securityfocus.com/bid/99234
- http://www.securitytracker.com/id/1038788
- https://ics-cert.us-cert.gov/advisories/ICSA-17-173-01
- https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-126840.pdf
JSON original (NVD)
Mostrar
{
"id": "CVE-2017-6868",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 6.8,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "MEDIUM",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 8.1,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.2
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "n/a",
"product": "Siemens SIMATIC CP 44x-1 Redundant Network Access Modules",
"versions": [
{
"status": "affected",
"version": "Siemens SIMATIC CP 44x-1 Redundant Network Access Modules"
}
]
}
]
}
],
"published": "2017-07-07T17:29:00.340",
"references": [
{
"url": "http://www.securityfocus.com/bid/99234",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "http://www.securitytracker.com/id/1038788",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-173-01",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-126840.pdf",
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "http://www.securityfocus.com/bid/99234",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.securitytracker.com/id/1038788",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-173-01",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-126840.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An Improper Authentication issue was discovered in Siemens SIMATIC CP 44x-1 RNA, all versions prior to 1.4.1. An unauthenticated remote attacker may be able to perform administrative actions on the Communication Process (CP) of the RNA series module, if network access to Port 102/TCP is available and the configuration file for the CP is stored on the RNA's CPU."
},
{
"lang": "es",
"value": "Se detectó un problema de autenticación inapropiada en SIMATIC CP 44x-1 RNA de Siemens, todas las versiones anteriores a 1.4.1. Un atacante remoto no autenticado puede ser capaz de realizar acciones administrativas en el Proceso de Comunicación (CP) del módulo de la serie RNA, si el acceso de red al puerto 102/TCP está disponible y el archivo de configuración para el CP se salva en la CPU del RNA."
}
],
"lastModified": "2026-06-17T01:23:14.720",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:simatic_cp_44x-1_redundant_network_access_modules:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D0D86C69-26D1-482A-BB8D-B5976628CBC8",
"versionEndIncluding": "1.4.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}