« Volver al listado

CVE-2017-5822

Estado: ModificadaAlta (7.5)—

A Remote Code Execution vulnerability in HPE Intelligent Management Center (iMC) PLAT version 7.3 E0504P04 was found.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2017-5822",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 7.8,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:C/A:N",
          "authentication": "NONE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "LOW",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 6.9,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "security-alert@hpe.com",
      "affectedData": [
        {
          "vendor": "Hewlett Packard Enterprise",
          "product": "Intelligent Management Center (iMC) PLAT",
          "versions": [
            {
              "status": "affected",
              "version": "PLAT 7.3 E0504P04"
            }
          ]
        }
      ]
    }
  ],
  "published": "2018-02-15T22:29:07.217",
  "references": [
    {
      "url": "http://www.securitytracker.com/id/1038560",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "security-alert@hpe.com"
    },
    {
      "url": "https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-hpesbhf03746en_us",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "security-alert@hpe.com"
    },
    {
      "url": "http://www.securitytracker.com/id/1038560",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-hpesbhf03746en_us",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A Remote Code Execution vulnerability in HPE Intelligent Management Center (iMC) PLAT version 7.3 E0504P04 was found."
    },
    {
      "lang": "es",
      "value": "Se ha encontrado una vulnerabilidad de ejecución remota de código en HPE Intelligent Management Center (iMC) PLAT 7.3 E0504P04."
    }
  ],
  "lastModified": "2026-06-17T01:21:15.280",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:hp:intelligent_management_center:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "70962382-6FA5-4E21-81D8-09FE48D77A54",
              "versionEndExcluding": "7.3"
            },
            {
              "criteria": "cpe:2.3:a:hp:intelligent_management_center:7.3:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "2D65BCDB-0795-4DE6-8B33-BCB636DD9D25"
            },
            {
              "criteria": "cpe:2.3:a:hp:intelligent_management_center:7.3:e0503p02:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E205ACEE-9DB1-449F-855C-3A71DF35000C"
            },
            {
              "criteria": "cpe:2.3:a:hp:intelligent_management_center:7.3:e0504p02:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "16728216-DDCF-4842-9C7F-02FE7E055E70"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com"
}