« Volver al listado

CVE-2017-3580

Estado: ModificadaAlta (8.3)—

Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: RAS subsystems). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products.

Leer descripción completaMostrar menos

Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.3 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H).

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2017-3580",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2017-3580",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-10-04T16:22:06.477248Z"
        }
      }
    ],
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 5.1,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:H/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "HIGH",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 4.9,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.0",
          "baseScore": 8.3,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "HIGH",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 1.6
      }
    ]
  },
  "affected": [
    {
      "source": "secalert_us@oracle.com",
      "affectedData": [
        {
          "vendor": "Oracle Corporation",
          "product": "Sun ZFS Storage Appliance Kit (AK) Software",
          "versions": [
            {
              "status": "affected",
              "version": "AK 2013"
            }
          ]
        }
      ]
    }
  ],
  "published": "2017-04-24T19:59:05.380",
  "references": [
    {
      "url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "secalert_us@oracle.com"
    },
    {
      "url": "http://www.securityfocus.com/bid/97830",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "secalert_us@oracle.com"
    },
    {
      "url": "http://www.securitytracker.com/id/1038292",
      "source": "secalert_us@oracle.com"
    },
    {
      "url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.securityfocus.com/bid/97830",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.securitytracker.com/id/1038292",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: RAS subsystems). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.3 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H)."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad en el componente Sun ZFS Storage Appliance Kit (AK) de Oracle Sun Systems Products Suite (subcomponente: RAS subsystems). La versión soportada que se ve afectada es AK 2013. Difícil de explotar la vulnerabilidad permite un atacante no autenticado con acceso a la red a través de múltiples protocolos para comprometer Sun ZFS Storage Appliance Kit (AK). Los ataques exitosos requieren una interacción humana de una persona más que un atacante y aunque la vulnerabilidad está en el Kit de Dispositivos de Almacenamiento Sun ZFS, los ataques pueden afectar significativamente a otros productos. Los ataques exitosos de esta vulnerabilidad pueden resultar en la adquisición de Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.3 (Confidencialidad, Integridad y Impactos de disponibilidad). Vector CVSS: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H)."
    }
  ],
  "lastModified": "2026-06-17T01:18:37.833",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:oracle:sun_zfs_storage_appliance_kit:ak_2013:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D9B7B268-6120-4030-9EC6-39608F403352"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "secalert_us@oracle.com"
}