« Volver al listado

CVE-2017-2683

Estado: ModificadaAlta (8.2)—

A non-privileged user of the Siemens web application RUGGEDCOM NMS < V1.2 on port 8080/TCP and 8081/TCP could perform a persistent Cross-Site Scripting (XSS) attack, potentially resulting in obtaining administrative permissions.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2017-2683",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4.3,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.0",
          "baseScore": 8.2,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 4.7,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "RUGGEDCOM NMS All versions < V2.1 (Windows and Linux)",
          "versions": [
            {
              "status": "affected",
              "version": "RUGGEDCOM NMS All versions < V2.1 (Windows and Linux)"
            }
          ]
        }
      ]
    }
  ],
  "published": "2017-02-27T11:59:00.197",
  "references": [
    {
      "url": "http://www.securityfocus.com/bid/96455",
      "source": "productcert@siemens.com"
    },
    {
      "url": "http://www.securitytracker.com/id/1037958",
      "source": "productcert@siemens.com"
    },
    {
      "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-363881.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-059-01",
      "source": "productcert@siemens.com"
    },
    {
      "url": "http://www.securityfocus.com/bid/96455",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.securitytracker.com/id/1037958",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-363881.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-059-01",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A non-privileged user of the Siemens web application RUGGEDCOM NMS < V1.2 on port 8080/TCP and 8081/TCP could perform a persistent Cross-Site Scripting (XSS) attack, potentially resulting in obtaining administrative permissions."
    },
    {
      "lang": "es",
      "value": "Un usuario no privilegiado de la aplicación web de Siemens RUGGEDCOM NMS < V1.2 en puertos 8080/TCP y 8081/TCP podría realizar un ataque de XSS resultando potencialmente en la obtención de permisos administrativos."
    }
  ],
  "lastModified": "2026-06-17T01:16:39.637",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:ruggedcom_network_management_software:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6D72B13C-17A8-4530-970F-2BDB7F4B455C",
              "versionEndIncluding": "2.0.2"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}