CVE-2017-16339
Estado: ModificadaCrítica (9.9)—
An attacker could send an authenticated HTTP request to trigger this vulnerability in Insteon Hub running firmware version 1012. At 0x9d01bb1c the value for the uri key is copied using strcpy to the buffer at 0xa00016a0. This buffer is 64 bytes large, sending anything longer will cause a buffer overflow.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
- Puntuación base: 9.9
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.36%
- Percentil entre todas las CVEs puntuadas: 71
- Fecha de la puntuación: 7/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-120
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2017-16339",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 8,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:C",
"authentication": "SINGLE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 8.5,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "talos-cna@cisco.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.0",
"baseScore": 8.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 1.8
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 9.9,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 3.1
}
]
},
"affected": [
{
"source": "talos-cna@cisco.com",
"affectedData": [
{
"vendor": "Insteon",
"product": "Insteon",
"versions": [
{
"status": "affected",
"version": "Insteon Hub 2245-222 - Firmware version 1012"
}
]
}
]
}
],
"published": "2018-08-02T19:29:00.403",
"references": [
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0484",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "talos-cna@cisco.com"
},
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0484",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-120"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An attacker could send an authenticated HTTP request to trigger this vulnerability in Insteon Hub running firmware version 1012. At 0x9d01bb1c the value for the uri key is copied using strcpy to the buffer at 0xa00016a0. This buffer is 64 bytes large, sending anything longer will cause a buffer overflow."
},
{
"lang": "es",
"value": "Un atacante podría enviar una petición HTTP autenticada para desencadenar esta vulnerabilidad en Insteon Hub, con la versión 1012 de firmware. En 0x9d01bb1c, el valor de la clave del uri se copia mediante strcpy al búfer en 0xa00016a0. Este búfer tiene un tamaño de 64 bytes, por lo que el envío de algo más grande provocará un desbordamiento de búfer."
}
],
"lastModified": "2026-06-17T01:09:12.570",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:insteon:hub_firmware:1012:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "17F98B37-72C0-48A5-A4E2-12327F48327E"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:insteon:hub:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "951165BE-0AC1-4690-8B36-E402CA0197FB"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "talos-cna@cisco.com"
}