CVE-2017-11402
Estado: ModificadaCrítica (9.8)—
An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00. Design flaws in OPC classic and in custom netfilter modules allow an attacker to remotely activate rules on the firewall and to connect to any TCP port of a protected asset, thus bypassing the firewall. The attack methodology is a crafted OPC dynamic port shift.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.54%
- Percentil entre todas las CVEs puntuadas: 74
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-20
Referencias
- https://github.com/airbus-seclab/security-advisories/blob/master/belden/tofino.txt
- https://www.belden.com/hubfs/support/security/bulletins/Belden-Security-Bulletin-BSECV-2017-14-1v1-1.pdf
- https://github.com/airbus-seclab/security-advisories/blob/master/belden/tofino.txt
- https://www.belden.com/hubfs/support/security/bulletins/Belden-Security-Bulletin-BSECV-2017-14-1v1-1.pdf
JSON original (NVD)
Mostrar
{
"id": "CVE-2017-11402",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 10,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"authentication": "NONE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2017-11-20T15:29:00.340",
"references": [
{
"url": "https://github.com/airbus-seclab/security-advisories/blob/master/belden/tofino.txt",
"tags": [
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.belden.com/hubfs/support/security/bulletins/Belden-Security-Bulletin-BSECV-2017-14-1v1-1.pdf",
"tags": [
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://github.com/airbus-seclab/security-advisories/blob/master/belden/tofino.txt",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.belden.com/hubfs/support/security/bulletins/Belden-Security-Bulletin-BSECV-2017-14-1v1-1.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-20"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00. Design flaws in OPC classic and in custom netfilter modules allow an attacker to remotely activate rules on the firewall and to connect to any TCP port of a protected asset, thus bypassing the firewall. The attack methodology is a crafted OPC dynamic port shift."
},
{
"lang": "es",
"value": "Se ha descubierto un problema en las versiones anteriores a la 03.2.00 de Belden Hirschmann Tofino Xenon Security Appliance. Los fallos de diseño en módulos OPC classic y netfilter personalizados permiten que un atacante active remotamente las reglas en el firewall y se conecte a cualquier puerto TCP de un activo protegido, eludiendo el firewall. La metodología de ataque es un cambio de puertos OPC dinámicos."
}
],
"lastModified": "2026-06-17T01:01:44.990",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_xenon_security_appliance_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9FD9B53A-9BC6-4851-B75F-C491B1802A81",
"versionEndIncluding": "3.1.0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_xenon_security_appliance:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "1957DB06-C01D-4325-81B7-45FA93040101"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}