CVE-2016-9495
Estado: ModificadaAlta (8.8)—
Hughes high-performance broadband satellite modems, models HN7740S DW7000 HN7000S/SM, uses hard coded credentials. Access to the device's default telnet port (23) can be obtained through using one of a few default credentials shared among all devices.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.89%
- Percentil entre todas las CVEs puntuadas: 58
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (4)
CWE
- CWE-798
- CWE-798
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2016-9495",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5.8,
"accessVector": "ADJACENT_NETWORK",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 6.5,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 8.8,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "cret@cert.org",
"affectedData": [
{
"vendor": "Hughes Satellite Modem",
"product": "HN7740S",
"versions": [
{
"status": "unknown",
"version": "N/A"
}
]
},
{
"vendor": "Hughes Satellite Modem",
"product": "DW7000",
"versions": [
{
"status": "unknown",
"version": "N/A"
}
]
},
{
"vendor": "Hughes Satellite Modem",
"product": "HN7000S/SM",
"versions": [
{
"status": "unknown",
"version": "N/A"
}
]
}
]
}
],
"published": "2018-07-13T20:29:01.783",
"references": [
{
"url": "https://www.kb.cert.org/vuls/id/614751",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "cret@cert.org"
},
{
"url": "https://www.securityfocus.com/bid/96244",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cret@cert.org"
},
{
"url": "https://www.kb.cert.org/vuls/id/614751",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.securityfocus.com/bid/96244",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cret@cert.org",
"description": [
{
"lang": "en",
"value": "CWE-798"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-798"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Hughes high-performance broadband satellite modems, models HN7740S DW7000 HN7000S/SM, uses hard coded credentials. Access to the device's default telnet port (23) can be obtained through using one of a few default credentials shared among all devices."
},
{
"lang": "es",
"value": "Los módems por satélite de alto rendimiento de banda ancha de Hughes, en sus modelos HN7740S DW7000 HN7000S/SM, emplean credenciales embebidas. Se puede obtener acceso al puerto telnet por defecto (23) del dispositivo mediante el uso de un par de credenciales por defecto compartidas entre todos los dispositivos."
}
],
"lastModified": "2026-06-17T00:56:10.290",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hughes:hn7740s_firmware:6.9.0.34:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E9029731-A889-43E7-BBC0-38E982690D57"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hughes:hn7740s:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "BF1B8214-EE17-49B6-8084-D9195F989961"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hughes:dw7000_firmware:6.9.0.34:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A98920BD-1929-419A-961A-CA0F09187693"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hughes:dw7000:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "6A154763-BFF7-4541-9036-34B85BA18479"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hughes:hn7000s_firmware:6.9.0.34:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "27F4528C-7D87-4B5A-A330-A09F555AE36D"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hughes:hn7000s:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "91470E55-2227-489A-BEB5-86C151F32344"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hughes:hn7000sm_firmware:6.9.0.34:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BA234B78-E832-4493-BFCD-AECEAC3CCA02"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hughes:hn7000sm:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "5AAB1D14-3EA2-46C7-9010-87750F19DF24"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cret@cert.org"
}