Estado: ModificadaAlta (8)—

An issue was discovered in Fatek Automation PLC WinProladder Version 3.11 Build 14701. A stack-based buffer overflow vulnerability exists when the software application connects to a malicious server, resulting in a stack buffer overflow. This causes an exploitable Structured Exception Handler (SEH) overwrite condition that may allow remote code execution.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2016-8377",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 6,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:S/C:P/I:P/A:P",
          "authentication": "SINGLE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 6.8,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.1
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "Fatek Automation PLC WinProladder 3.11 Build 14701",
          "versions": [
            {
              "status": "affected",
              "version": "Fatek Automation PLC WinProladder 3.11 Build 14701"
            }
          ]
        }
      ]
    }
  ],
  "published": "2017-02-13T21:59:01.347",
  "references": [
    {
      "url": "http://www.securityfocus.com/bid/94938",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-350-01",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://www.exploit-db.com/exploits/42700/",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "http://www.securityfocus.com/bid/94938",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-350-01",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.exploit-db.com/exploits/42700/",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered in Fatek Automation PLC WinProladder Version 3.11 Build 14701. A stack-based buffer overflow vulnerability exists when the software application connects to a malicious server, resulting in a stack buffer overflow. This causes an exploitable Structured Exception Handler (SEH) overwrite condition that may allow remote code execution."
    },
    {
      "lang": "es",
      "value": "Ha sido descubierto un problema en Fatek Automation PLC WinProladder Version 3.11 Build 14701. Una vulnerabilidad de desbordamiento de búfer basado en pila existe cuando la aplicación de software se conecta a un servidor malicioso, resultando en un desbordamiento de búfer en pila. Esto provoca una condición de sobreescritura Structured Exception Handler (SEH) explotable que puede permitir la ejecución de código remoto."
    }
  ],
  "lastModified": "2026-06-17T00:54:14.777",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:fatek:plc_winproladder_firmware:3.11:build_14701:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8F110DC8-D913-45C6-AAC3-0C1396C4D73A"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:fatek:plc_winproladder:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "24E8C229-479D-49FD-98A7-0CCC4F2C5775"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}