CVE-2016-5813
Estado: ModificadaMedia (5.3)—
An issue was discovered in Visonic PowerLink2, all versions prior to October 2016 firmware release. When a specific URL to an image is accessed, the downloaded image carries with it source code used in the web server (INFORMATION EXPOSURE).
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
- Puntuación base: 5.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.23%
- Percentil entre todas las CVEs puntuadas: 68
- Fecha de la puntuación: 4/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-200
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2016-5813",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 5.3,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 1.4,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "n/a",
"product": "Visonic PowerLink2",
"versions": [
{
"status": "affected",
"version": "Visonic PowerLink2"
}
]
}
]
}
],
"published": "2017-02-13T21:59:00.470",
"references": [
{
"url": "http://www.securityfocus.com/bid/94894",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-01",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "http://www.securityfocus.com/bid/94894",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-01",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-200"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Visonic PowerLink2, all versions prior to October 2016 firmware release. When a specific URL to an image is accessed, the downloaded image carries with it source code used in the web server (INFORMATION EXPOSURE)."
},
{
"lang": "es",
"value": "Ha sido descubierto un problema en Visonic PowerLink2, todas las versiones anteriores a la versión de firmware de octubre de 2016. Cuando se accede a una URL específica hacia una imagen, la imagen descargada lleva consigo código fuente utilizado en el servidor web (INFORMATION EXPOSURE)."
}
],
"lastModified": "2026-06-17T00:50:04.683",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:visonic:powerlink2_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E4D1C970-1942-4EB6-8CA4-17E6B66E96F1"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:visonic:powerlink2:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "B5F51142-2C8F-44F6-988B-6A0C0F822B56"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}