« Volver al listado

CVE-2015-6466

Estado: ModificadaMedia (4.3)—

Cross-site scripting (XSS) vulnerability in the Diagnosis Ping feature in the administrative web interface on Moxa EDS-405A and EDS-408A switches with firmware before 3.6 allows remote attackers to inject arbitrary web script or HTML via an unspecified field.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2015-6466",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4.3,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2015-09-11T16:59:10.423",
  "references": [
    {
      "url": "http://www.moxa.com/support/download.aspx?type=support&id=328",
      "tags": [
        "Patch"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-246-03",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "http://www.moxa.com/support/download.aspx?type=support&id=328",
      "tags": [
        "Patch"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-246-03",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Cross-site scripting (XSS) vulnerability in the Diagnosis Ping feature in the administrative web interface on Moxa EDS-405A and EDS-408A switches with firmware before 3.6 allows remote attackers to inject arbitrary web script or HTML via an unspecified field."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de XSS en la funcionalidad Diagnosis Ping en la interfaz web administrativa en switches Moxa EDS-405A y EDS-408A con firmware anterior a 3.6, permite a atacantes remotos inyectar secuencias de comandos web o HTML arbitrarios a través de un campo no especificado."
    }
  ],
  "lastModified": "2026-06-17T00:30:55.020",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:eds-405a_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "97242DF5-7719-4B87-A32A-6586AC29B43E",
              "versionEndIncluding": "3.4"
            },
            {
              "criteria": "cpe:2.3:o:moxa:eds-408a_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "06AB2766-5CD1-4491-8825-ED6B6CDD49A8",
              "versionEndIncluding": "3.4"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:eds-405a:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "66C5DF82-A91D-4966-A841-5B5235316ED4"
            },
            {
              "criteria": "cpe:2.3:h:moxa:eds-408a:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "316407E3-51E2-4622-99CE-B683B91741D3"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}