CVE-2015-2746
Estado: ModificadaMedia (6.5)—
The network diagnostics tool (CommandLineServlet) in the Appliance Manager command line utility (CLU) in Websense TRITON 7.8.3 and V-Series appliances before 7.8.4 Hotfix 02 allows remote authenticated users to execute arbitrary commands via shell metacharacters in the "second" parameter of a command, as demonstrated by the Destination parameter in the ping command.
CVSS
- Versión: 2.0
- Vector: AV:N/AC:L/Au:S/C:P/I:P/A:P
- Puntuación base: 6.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 25%
- Percentil entre todas las CVEs puntuadas: 98
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-77
Referencias
- http://packetstormsecurity.com/files/130899/Websense-Appliance-Manager-Command-Injection.html
- http://seclists.org/fulldisclosure/2015/Mar/104
- http://www.securityfocus.com/archive/1/534910/100/0/threaded
- http://www.websense.com/support/article/kbarticle/October-2014-Hotfix-Summary-for-Websense-Solutions
- https://www.exploit-db.com/exploits/36423/
- https://www.securify.nl/advisory/SFY20140906/command_injection_vulnerability_in_network_diagnostics_tool_of_websense_appliance_manager.html
- http://packetstormsecurity.com/files/130899/Websense-Appliance-Manager-Command-Injection.html
- http://seclists.org/fulldisclosure/2015/Mar/104
- http://www.securityfocus.com/archive/1/534910/100/0/threaded
- http://www.websense.com/support/article/kbarticle/October-2014-Hotfix-Summary-for-Websense-Solutions
- https://www.exploit-db.com/exploits/36423/
- https://www.securify.nl/advisory/SFY20140906/command_injection_vulnerability_in_network_diagnostics_tool_of_websense_appliance_manager.html
JSON original (NVD)
Mostrar
{
"id": "CVE-2015-2746",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 6.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"authentication": "SINGLE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2015-03-26T14:59:03.727",
"references": [
{
"url": "http://packetstormsecurity.com/files/130899/Websense-Appliance-Manager-Command-Injection.html",
"tags": [
"Exploit"
],
"source": "cve@mitre.org"
},
{
"url": "http://seclists.org/fulldisclosure/2015/Mar/104",
"source": "cve@mitre.org"
},
{
"url": "http://www.securityfocus.com/archive/1/534910/100/0/threaded",
"source": "cve@mitre.org"
},
{
"url": "http://www.websense.com/support/article/kbarticle/October-2014-Hotfix-Summary-for-Websense-Solutions",
"tags": [
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.exploit-db.com/exploits/36423/",
"source": "cve@mitre.org"
},
{
"url": "https://www.securify.nl/advisory/SFY20140906/command_injection_vulnerability_in_network_diagnostics_tool_of_websense_appliance_manager.html",
"tags": [
"Exploit"
],
"source": "cve@mitre.org"
},
{
"url": "http://packetstormsecurity.com/files/130899/Websense-Appliance-Manager-Command-Injection.html",
"tags": [
"Exploit"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://seclists.org/fulldisclosure/2015/Mar/104",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.securityfocus.com/archive/1/534910/100/0/threaded",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.websense.com/support/article/kbarticle/October-2014-Hotfix-Summary-for-Websense-Solutions",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.exploit-db.com/exploits/36423/",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.securify.nl/advisory/SFY20140906/command_injection_vulnerability_in_network_diagnostics_tool_of_websense_appliance_manager.html",
"tags": [
"Exploit"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The network diagnostics tool (CommandLineServlet) in the Appliance Manager command line utility (CLU) in Websense TRITON 7.8.3 and V-Series appliances before 7.8.4 Hotfix 02 allows remote authenticated users to execute arbitrary commands via shell metacharacters in the \"second\" parameter of a command, as demonstrated by the Destination parameter in the ping command."
},
{
"lang": "es",
"value": "La herramienta de la diagnóstica de la red (CommandLineServlet) la utilidad de líneas de comandos (CLU) de Appliance Manager en Websense TRITON 7.8.3 y las aplicaciones de la serie V anterior a 7.8.4 Hotfix 02 permite a usuarios remotos autenticados ejecutar comandos arbitrarios a través de metacaracteres de shell en el parámetro 'second' de un comando, tal y como fue demostrado por el parámetro Destination en el comando ping."
}
],
"lastModified": "2026-06-17T00:24:40.570",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:websense:triton:7.8.3:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E449CF3F-D1F2-4A21-A193-E2179C87A982"
},
{
"criteria": "cpe:2.3:a:websense:v-series_appliances:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FBBE6A6B-D529-4C46-91EA-4204FC3CDA43",
"versionEndIncluding": "7.7"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cve@mitre.org"
}