CVE-2014-9204
Estado: ModificadaMedia (6.9)—
Stack-based buffer overflow in OPCTest.exe in Rockwell Automation RSLinx Classic before 3.73.00 allows remote attackers to execute arbitrary code via a crafted CSV file.
CVSS
- Versión: 2.0
- Vector: AV:L/AC:M/Au:N/C:C/I:C/A:C
- Puntuación base: 6.9
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.57%
- Percentil entre todas las CVEs puntuadas: 75
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-119
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2014-9204",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 6.9,
"accessVector": "LOCAL",
"vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
"authentication": "NONE",
"integrityImpact": "COMPLETE",
"accessComplexity": "MEDIUM",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 3.4,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2015-05-17T01:59:00.080",
"references": [
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-111-02",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/646324",
"tags": [
"Permissions Required"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-111-02",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/646324",
"tags": [
"Permissions Required"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-119"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Stack-based buffer overflow in OPCTest.exe in Rockwell Automation RSLinx Classic before 3.73.00 allows remote attackers to execute arbitrary code via a crafted CSV file."
},
{
"lang": "es",
"value": "Desbordamiento de buffer basado en pila en OPCTest.exe en Rockwell Automation RSLinx Classic anterior a 3.73.00 permite a atacantes remotos ejecutar código arbitrario a través de un fichero CSV manipulado."
}
],
"lastModified": "2026-06-17T00:17:55.520",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rockwellautomation:rslinx:*:*:*:*:classic:*:*:*",
"vulnerable": true,
"matchCriteriaId": "376B4AF7-335D-4671-8149-94A29CCD04E6",
"versionEndExcluding": "3.73.00"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}