« Volver al listado

CVE-2014-0755

Estado: ModificadaMedia (6.9)—

Rockwell Automation RSLogix 5000 7 through 20.01, and 21.0, does not properly implement password protection for .ACD files (aka project files), which allows local users to obtain sensitive information or modify data via unspecified vectors.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2014-0755",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Secondary",
        "source": "ics-cert@hq.dhs.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 6.3,
          "accessVector": "LOCAL",
          "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:N",
          "authentication": "NONE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 9.2,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 3.4,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 6.9,
          "accessVector": "LOCAL",
          "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
          "authentication": "NONE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 3.4,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "Rockwell Automation",
          "product": "RSLogix 5000 software",
          "versions": [
            {
              "status": "affected",
              "version": "V7",
              "versionType": "custom",
              "lessThanOrEqual": "V20.01"
            },
            {
              "status": "affected",
              "version": "V7",
              "versionType": "custom",
              "lessThanOrEqual": "V21.0"
            },
            {
              "status": "unaffected",
              "version": "V20.03"
            },
            {
              "status": "unaffected",
              "version": "V21.03"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2014-02-05T05:15:29.930",
  "references": [
    {
      "url": "http://osvdb.org/102858",
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "http://www.securityfocus.com/bid/65337",
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/90981",
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/565204",
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-021-01",
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-021-01",
      "tags": [
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://osvdb.org/102858",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.securityfocus.com/bid/65337",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/90981",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "ics-cert@hq.dhs.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-522"
        }
      ]
    },
    {
      "type": "Secondary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-255"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Rockwell Automation RSLogix 5000 7 through 20.01, and 21.0, does not properly implement password protection for .ACD files (aka project files), which allows local users to obtain sensitive information or modify data via unspecified vectors."
    },
    {
      "lang": "es",
      "value": "Rockwell Automation RSLogix 5000 7 hasta 20.01 y 21.0, no implementa debidamente la protección por contraseña de archivos .ACD (también conocidos como archivos de proyecto), lo cual permite a usuarios locales obtener información sensible o modificar datos a través de vectores no especificados."
    }
  ],
  "lastModified": "2026-06-17T00:03:34.993",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rockwellautomation:rslogix_5000_design_and_configuration_software:7.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B25AFECC-3BDB-4F8D-AC6E-D3432DE86966"
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:rslogix_5000_design_and_configuration_software:18.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "038A8096-81C1-4C1D-B042-48869FE23285"
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:rslogix_5000_design_and_configuration_software:20.01:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "BB4DEEC1-BDFF-48F6-A4A9-E971106DA8F5"
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:rslogix_5000_design_and_configuration_software:21.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "5C298300-3C38-4899-9424-C2CB1C37ABA5"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:logix_5000_controller:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "C588EA2D-A90A-4B68-98F9-9C0072BFA473"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}