CVE-2013-2805
Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it receives a datagram with an incorrect value in the “Record Data Size” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to an oversized value, an attacker could cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to this vulnerability can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 3.85%
- Percentil entre todas las CVEs puntuadas: 90
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-125
- CWE-125
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2013-2805",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.8,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 6.9,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "Rockwell Automation",
"product": "RSLinx Enterprise Software",
"versions": [
{
"status": "affected",
"version": "CPR9"
},
{
"status": "affected",
"version": "CPR9-SR1"
},
{
"status": "affected",
"version": "CPR9-SR2"
},
{
"status": "affected",
"version": "CPR9-SR3"
},
{
"status": "affected",
"version": "CPR9-SR4"
},
{
"status": "affected",
"version": "CPR9-SR5"
},
{
"status": "affected",
"version": "CPR9-SR5.1"
},
{
"status": "affected",
"version": "CPR9-SR6"
}
]
}
]
}
],
"published": "2019-03-26T18:29:00.310",
"references": [
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-13-095-02",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-13-095-02",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it receives a datagram with an incorrect value in the “Record Data Size” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to an oversized value, an attacker could cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to this vulnerability can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599"
},
{
"lang": "es",
"value": "El software RSLinx Enterprise de Rockwell Automation (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1 y CPR9-SR6 no maneja la entrada correctamente y da como resultado un error lógico si recibe un datagrama con un valor incorrecto en el campo\" Record Data Size”. Al enviar un datagrama al servicio a través del puerto 4444 / UDP con el campo “Record Data Size” modificado a un valor demasiado grande, un atacante podría causar una infracción de acceso de lectura fuera de los límites que conduzca a un bloqueo del servicio. El servicio se puede recuperar con un reinicio manual. Los parches y detalles relacionados con esta vulnerabilidad se pueden encontrar en el siguiente enlace de aviso de seguridad de Rockwell Automation (se requiere inicio de sesión): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599"
}
],
"lastModified": "2026-06-16T23:53:59.643",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rockwellautomation:rslinx_enterprise:5.10.00:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D42DF440-5AC1-4B7D-9A32-A30E2807D21B"
},
{
"criteria": "cpe:2.3:a:rockwellautomation:rslinx_enterprise:5.10.01:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "436B1B6F-7B5F-4851-A04B-8E4FD1CCE75B"
},
{
"criteria": "cpe:2.3:a:rockwellautomation:rslinx_enterprise:5.20.00:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "ECE341BF-F144-4F44-A232-0F4CB97CEAFF"
},
{
"criteria": "cpe:2.3:a:rockwellautomation:rslinx_enterprise:5.21.00:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9B9B5530-419A-4587-A1D9-9E92ABB99300"
},
{
"criteria": "cpe:2.3:a:rockwellautomation:rslinx_enterprise:5.30.00:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "49BDD83C-D14A-434D-BA89-8451011C5F07"
},
{
"criteria": "cpe:2.3:a:rockwellautomation:rslinx_enterprise:5.40.00:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7C37C557-4DA4-4A4F-8F5A-33DF41D37C45"
},
{
"criteria": "cpe:2.3:a:rockwellautomation:rslinx_enterprise:5.50.00:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6F17A84F-CFA8-4BA9-A3D5-9044F53FC9FF"
},
{
"criteria": "cpe:2.3:a:rockwellautomation:rslinx_enterprise:5.51.00:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4648726F-63DB-4F97-9A20-B224FDE5AA53"
},
{
"criteria": "cpe:2.3:a:rockwellautomation:rslinx_enterprise:5.60.00:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "33F649D7-E46D-4378-B044-ABC7C20D1AAD"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}